Operation Instructions for Versati III
[Notes]
At the commissioning parameter setting page, when the state of any function changes, the system will
automatically save this change and this change will remain upon power failure.
Do not modify any commissioning parameter except the approved qualified servicemen, as it would give birth to
adverse effects to the unit.
No.
Item
1
Ctrl. state
2-Way
2
valve
Solar
5
setting
6
Water tank
7
Thermostat
Other
8
thermal
Optional
9
E-Heater
Remote
10
sensor
11
Air removal
12
Floor debug
Manual
13
defrost
14
Force mode
15
Tank heater
16
Gate-Ctrl.
Current
17
Limit
18
Address
Refri.
19
recovery
Commissioning Function Setting
Range
T-water out/T-room
Cool 2-Way valve, On/Off
Heat 2-Way valve, On/Off
With/Without
With/Without
Without/Air/Air+ hot water
With/Without
Off/1/2
With/Without
On/Off
On/Off
On/Off
Off/Force-cool/Force-heat
Logic 1/Logic 2
On/Off
On/Off
[1-125] [127-253]
On/Off
Default
When "Remote sensor" is set to "With", it can
T-water out
be set to "T-room".
It will decide the status of the 2-way valve under
Off
the "Cool" and "Cool + Hot water" modes.
It will decide the status of the 2-way valve under
On
the "Heat" and "Heat + Hot water" modes
When the water tank is unavailable, this setting
will be reserved.
When it is set to "With", the solar kitting will work
Without
on its own.
When it is set to "Without", hot water by the
solar kitting is unavailable.
Without
This setting cannot be interchanged between
Without
"Air" and "Air+ hot water" directly but via
"Without" this option
Without
/
Off
/
When it set to "Without", and the "Ctrl. state" will
Without
be defaulted to be "T-water out".
Off
/
Off
/
Off
/
Off
This setting is allowed when the water tank is
Logic 1
available and the unit is OFF.
Off
Off
It ranges from 0 to 50A and the default is 16A.
1
Off
15
Description
/
/
/
/