Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operation Instructions for Versati III
[Notes]
●This setting can be activated only when "Water tank" is set to "With". When "Water tank" is set to "Without",
this function will be deactivated.
●This setting can be done no matter if the unit is turned on or off.
● When "Emergen.mode", "Holiday mode", "Floor debug", "Manual defrost", or "Refri. recovery" has been
activated, this function cannot be activated at the same time. When "Disinfection" has been activated, "Emergen.
mode", "Holiday mode", "Floor debug" "Manual defrost", or "Refri. recovery" setting will fail and a window
will pop up, saying "Please disable the disinfect mode!"
● "Disinfection" can be activated no matter if the unit is turned on or off. This mode will take priority over the "Hot
water" mode.
● When disinfection operation fails, the display panel will tell "Disinfection fail!". Then, by pressing OK it will be
cleared.
● When "Disinfection" has been activated, if communication error with the indoor unit or malfunction of the
water tank heater occurs, it will automatically quit.
●It will be memorized upon power failure.

2.2.10 Clock Timer

[Operation Instructions]
1.At the function setting page, access to the "Clock timer" setting page.
2.At the "Clock timer" setting page, it can be set to "On" or "Off".
3.The option "Mode" is used to time the desired mode; "WOT-Heat" and "T-water tank" is used to set the
corresponding water temperature; "Period" is used to for time setting. After that, by touching the "Save" icon, all
settings will be saved.
9

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido