"DEWY EQUIPE P100 BOX"
SINGLE MODULE MALFUNCTIONS
– Ignition lock (fig. 3)
If the burner does not light the red led ( )
turns on. To attempt ignition again, rotate
the selector knob to ( ) and release it
immediately after returning it to winter
operations (
).
If it locks again, request an authorised
service control.
– Insufficient water pressure (fig. 4)
If the "0.5 bar" red light blinks, the
module does not work. To restore opera-
tions, fill the system until the green "1
bar" led turns on. If all leds are of f,
request an authorised service call.
– Safety/exhaust thermostat
triggered (fig. 5)
If the safety/exhaust thermostat trig-
gers the red "35°C" led blinks.
To attempt ignition again, rotate the
selector knob to ( ) and release it imme-
diately after returning it to winter opera-
tions (
).
If it locks again, request an authorised
service control.
– Other faults (fig. 6)
When one of the red "40÷80°C" leds
blinks, turn off the generator and attempt
ignition again.
This operation can be repeated 2-3 times
at most, in the event of failure, request an
authorised service call