Ariston GENUS PREMIUM HP 45 Instrucciones De Instalación Y De Utilización página 37

Ocultar thumbs Ver también para GENUS PREMIUM HP 45:
Tabla de contenido

Publicidad

menús de selección - regulación - diagnóstico
description
0 SETTING LANGUAGE - DATE - TIME
1 PROGRAMMING TIMER
2 BOILER PARAMETER SETTING
2 1 Entering access code
2 2 BOILER GENERAL SETTING
2 2 0 Slow ignition
2 2 1 Minimum ambient temperature for
antifreeze activation
2 2 2 NOT PRESENT
2 2 3 Underfl oor thermostat or zone 2
ambient thermostat selection
2 2 4 NOT PRESENT
2 2 5 Heating ignition delay
2 2 6 NOT PRESENT
2 2 7 NOT PRESENT
2 2 8 Boiler Version
2 3 BOILER PARAMETER - PART 1
2 3 0 NOT PRESENT
2 3 1 Maximum heating power setting
2 3 2 Domestic hot water maximum RPM
percentage
CANNOT BE MODIFIED
2 3 3 Minimum RPM percentage
CANNOT BE MODIFIED
2 3 4 Heating maximum RPM percentage
CANNOT BE MODIFIED
2 3 5 Selection of ignition delay type when
heating
2 3 6 Ignition delay when heating timer
setting
2 3 7 Post-circulation when heating
2 3 8 Circulation pump operating type
2 3 9 Setting the Delta T
Circulation pump modulation
These parameters allow the fl ow and backfl ow temperature diff erence to be set, which determines whether the circulation
pump switches from low to high speed
E.g.: param. 239 = 20 and ΔT > 20°C- the circulation pump runs at high speed. If ΔT < 20 - 2°C the circulation pump runs at
low speed. The minimum waiting time for changing speed is 5 minutes.
settings - adjustment - problem identifi cation menus
value
0 to 99
from 2 to 10 °C
0 = Floor safety thermostat
1 = Zone 2 ambient
thermostat
0 = Deactivated
1 = 10 seconds
2 = 90 seconds
3 = 210 seconds
0 to 5
0 = DO NOT USE
1 = Tank with NTC sensor
2 = Tank with thermostat
3 - 4 - 5 = DO NOT USE
0 to 99
0 to 99
0 to 99
0 to 99
0 = Manual
1 = automatic
from 0 to 7 minutes
from 0 to 15 minutes or OC
(AC)
0 = Low Speed
1 = High Speed
2 = Modulating
from 10 to 30 °C
See user manual
See user manual
222 turn the encoder clockwise to select 234 and
press the M
button
ENU
60
RESERVED FOR SAT
5
Activated only with the modulating
peripheral device (optional)
0
0
Activated only with zone 2 interface
(optional)
1
RESERVED FOR TECHNICAL ASSISTANCE Only
if the PCB is changed
see the "gas setting" table, information on
Starting
RESERVED FOR TECHNICAL ASSISTANCE Only
if the gas or PCB is changed
see "gas setting" table
1
see section on "gas setting"
3
3
2
20
to be set with operation of the circulation
pump in modulating mode
37

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Genus premium hp 65Genus premium hp 85Genus premium hp 100

Tabla de contenido