Ariston GENUS PREMIUM HP 45 Instrucciones De Instalación Y De Utilización página 43

Ocultar thumbs Ver también para GENUS PREMIUM HP 45:
Tabla de contenido

Publicidad

menús de selección - regulación - diagnóstico
description
5 ZONE 2 PARAMETER
5 0 ZONE 2 TEMPERATURE SETTING
5 0 0 Zone 2 comfort temperature setting
5 0 1 Zone 2 reduced temperature setting
5 0 2 Heating fi xed temperature setting
5 1 Entering access code
5 2 ZONE 2 SETTING
5 2 0 Heating appliance temperature value
setting
5 2 1 Basic heating control type selection
type depending on the peripheral
devices connected
5 2 2 Slope
If the external sensor is used, the boiler calculates the most suitable heating
fl ow temperature taking the external temperature and the type of appliance
into account.
The type of curve must be chosen according to the type of appliance radiator
and the heat losses present in the building.
5 2 3 Parallel shift
To adapt the thermal curve to the appliance requirements, it is possible to perform a parallel shift of the curve in order to alter
the calculated fl ow temperature and therefore the ambient temperature.
The shift value between - 20 and + 20 is shown on the display. Each level corresponds to a 1°C increase in the fl ow temperature
in relation to the initial setting.
5 2 4 Compensation
5 2 5 Zone 2 heating maximum temperature
setting
5 2 6 Zone 2 heating minimum temperature
setting
5 3 DIAGNOSTICS
5 3 0 Zone 2 room temperature
5 3 1 Heating fl ow outlet temperature
5 3 2 Heating return temperature
5 3 3 Zone 2 set temperature
5 3 4 Zone 2 heat request
5 3 5 Zone 2 Pump status
5 4 ZONE DEVICE MANAGEMENT
5 4 0 Operation mode test
5 4 1 Valve control
5 4 2 Pump control
5 5 MULTIZONE
5 5 0 Heating collector temperature
5 5 1 Heating collector fl ow outlet
temperature off set
settings - adjustment - problem identifi cation menus
value
from 10 to 30 °C
from 10 to 30 °C
from 20 to 82 °C
0 = from 20 to 45°C (low temp.)
1 = from 35 to 85°C (high temp.)
0 = fi xed fl ow temperature
1 = device On/Off
2 = ambient sensor only
3 = external sensor only
4 = ambient sensor +
external sensor
0_2 to 3_5
- 20 to + 20
0 to + 20
if setting = 0, the temperature taken from the ambient sensor does not aff ect the
calculation of the setting.
If setting = 20, the temperature taken has maximum infl uence on the setting.
35 to + 82°C
20 to + 45°C
35 to + 82°C
20 to + 45°C
0=OFF - 1=ON
0=OFF - 1=ON
0=OFF
1=ON
2=manual
0=OFF
1=Open
2=Close
0=OFF
1=ON
0 to 120°C
0 to + 40°C
19
Activated only with the modulating device
connected (option)
16
70
Activated only with temperature control and
fi xed temperature
222
turn the encoder clockwise to select 234 and
press the M
/O
button
ENU
K
1
select in the appliance type base
0
To activate heating control, press the AUTO
button. The display lights up the AUTO
symbol, indicating the peripheral device
connected (if present)
1_5
see graph on the previous page
0
20
82
if parameter 420 = 1
45
if parameter 420 = 0
35
if parameter 420 = 1
20
if parameter 420 = 0
Activated only with the modulating device
connected (option)
Only active with Heating Zones Modules
Management
Activated only with the modulating device
connected (option)
Only active with Heating Zones Modules
Management
Only active with Heating Zones Modules
Management
0
Only active with Heating Zones Modules
5
Management
43

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Genus premium hp 65Genus premium hp 85Genus premium hp 100

Tabla de contenido