Technical Specifications - BFT SIRIO FR-TMA Instrucciones De Uso Y De Instalacion

Central de mando
Ocultar thumbs Ver también para SIRIO FR-TMA:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
Thank you for buying this product, our company is sure that you will be more
than satisfied with its performance. This product is supplied with an
"Instruction Manual" which should be read carefully as it provides important
information about safety, installation, operation and maintenance.
This product complies with recognised technical standards and safety
regulations.This product complies with the recognised technical standards
and safety regulations. We declare that this product is in conformity with the
following European Directives: 89/336/EEC and 73/23/EEC, 98/37/CEE
(and subsequent amendments). with the following Technical Standards
EN60335-1, PrEN12453 and PrEN12445.
WARNINGS
When carrying out wiring and installation work, always refer to current
standards and good technical principles.
WARNINGS
Any assistance required on automation components must be carried out by
a qualified technician (installer).
1) GENERAL OUTLINE (Fig.1)
The control panel, equipped with a microprocessor control unit, is used to
operate single-phase or three-phase controllers fitted on sliding gates and
sectional doors. It is provided with a lockable switch, open/close/stop
buttons and a warning light for anomalies (e.g. release activated, overstroke).
A series of LEDs allows to check or detect any operating anomalies in the
control unit or on the connected devices. The control unit is supplied with
Dip-switches and Trimmers which provide configuration and calibration,
respectively. Self-diagnosis: the control unit allows a check to be carried out
on operating relays and safety devices (photocells, rubber edge etc.)
before any manoeuvre takes place.
2) GENERAL SAFETY
WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.
The "Warnings" leaflet and "Instruction booklet" supplied with this
product should be read carefully as they provide important information
about safety, installation, use and maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children's reach.
Keep the instructions together with the technical brochure for future
reference.
This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.
The Company declines all responsibility for any consequences resulting
from improper use of the product, or use which is different from that
expected and specified in the present documentation.
Do not install the product in explosive atmosphere.
The Company declines all responsibility for any consequences resulting
from failure to observe Good Technical Practice when constructing
closing structures (door, gates etc.), as well as from any deformation
which might occur during use.
The installation must comply with the provisions set out by the following
European Directives: 89/336/EEC, 73/23/EEC, 98/37/ECC and
subsequent amendments.
Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.
Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3mm.
Check that a differential switch with a 0.03A threshold is fitted just
before the power supply mains.
Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.
The Company declines all responsibility with respect to the automation
safety and correct operation when other manufacturers' components
are used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly authorised
by the company.
Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
Do not allow persons or children to remain in the automation operation
area.
Keep radio control or other control devices out of children's reach, in
order to avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair on the
automation system, and always request the assistance of qualified
personnel.
INSTALLATION MANUAL
Anything which is not expressly provided for in the present instructions,
is not allowed.

3) TECHNICAL SPECIFICATIONS

Power supply (*):.......................400 vac three-phase230 vac single-phase
Motor output current:...................................................................... 2A 4A
Motor output comm. current:..........................................................8A 12A
Mains - low voltage insulation:..................................... > 2MOhm 500Vdc
Mains - low voltage dielectric strength:.....................................3750Vac 1'
Maximum motor power: ........................................................750W 375W
Power supply to accessories:..............................24Vac/0,5A 24Vac/0,5A
Gate-open warning light:...................................................24V/3W 24/3W
Blinker:................................................................... 230V/40W 230V/40W
Dimensions:.................................................................................see fig.1
(*) (other voltages on request)
4) CONNECTIONS (Fig.3)
WARNINGS - For wiring and installation operations, refer to the current
standards and good technical principles.
Wires powered at different voltages must be physically separated, or
suitably insulated with at least 1 mm extra insulation. The wires must be
clamped by an extra fastener near the terminals, for example by bands.
WARNING! For connection to the mains, use a multipolar cable with
a minimum of 3x1.5mm
previously mentioned regulations. For example, if the cable is out
side (in the open), it has to be at least equal to H07RN-F, but if it is on
the inside (or outside but placed in a plastic cable cannel) it has to
be or at least egual to H05VV-F with section 3x1.5mm
N.B.: Before connecting the control unit to the mains voltage, check that
the JP5 (voltage change) terminal is preset for the correct working voltage.
The board is supplied with a series of previously bridged terminals.
The jumpers refer to the following terminals: 26-29, 26-30, 26-31, 26-35.
If these terminals are not used, leave them bridged. In the additional
terminal board SSBB1, the terminals 6-7, 8-9 and 10-11 are bridged.
If these terminals are not used, leave them bridged.
PANEL
Caution: the panel power supply must be connected to the "S" breaker.
S - THREE- PHASE
R-S-T-N......................................Three-phase 400V ±10% 50Hz + Neutral.
CAUTION! (voltage change JP5/39-40).
S - SINGLE-PHASE
R-N.............................................................Single-phase 230V ±10% 50Hz.
CAUTION! (voltage change JP5/40-41).
CONTROL UNIT
JP1 - THREE-PHASE
1-2-3-4 Three-phase power supply+neutral 400V.
5-6-7
8-9
JP1 - SINGLE-PHASE
1-2
5-6-7
8-9
JP2
10-11
11-12
12-13
14
15
16-17
18-19
JP7
20-21-22
23-24-25 Outputs for the connection of safety devices which are to be
JP4
26-27
2
cross section and complying with the
(1 Neutral, 2-3-4 phase)(Note: JP5 jumper between 39-40).
Three-phase motor connection.
230Vac output for blinker.
Single-phase power supply 230V.
(1 Neutral, 2 phase) (N.B.: JP5 jumper between 40-41).
Single-phase motor connection (5-7 motor and capacitor
operation, 6 common terminal).
230Vac output for blinker.
24Vac (3W) output for light indicating motor and/or pedestrian
access release. The light switches on when the motor is released
(manual operation) or the pedestrian access is open.
24Vac power supply to accessories and safety devices which are
not checked.
24VTx power supply only for safety device transmitters which are
checked.
LOOP1 input for safety device check ring (see fig.5).
LOOP2 input for safety device check ring (see fig.5).
Second radio channel output for two-channel receiver board
(n.o.).
Antenna input for radio receiver board (18 signal, 19 braid).
checked (see fig.5).
START button (n.o.).
ENGLISH
2
.
13
SIRIO FR - TMA - Ver. 09 -

Publicidad

Tabla de contenido
loading

Tabla de contenido