Building In

Fig. 2
Dimensions are given in millimetres
These hobs can be inserted in a built-in kitchen unit whose
depth is between 550 and 600 mm. The hobs dimensions
are shown in Fig. 2.
Installation and assembly
These hobs can be installed in a kitchen unit with an
opening for insertion whose dimensions are shown in
Fig. 3.
The edge of the cut out must have a minimum distance
from the rear wall of 55 mm.
If there are side walls, or sides of the furniture unit near
the hob, the cut out edges must have a minimum distance
of 100 mm.
Hanging forniture units or hoods must be placed at 650
mm minimum from the hob.
Carry out the building in of the hob as follows:
1. Place the sealing gasket (Fig.4 - "A") all around the
edge of the cut out.
2. Fit the hob in the cut out and push it down until it
comes in contact with the kitchen top surface. Then
remove the excess sealing.
3. To remove the hob from the cut-out, lift the edge of the
hob by means of the edge of a screw-driver.
If several 30cm hob are to be installed side by
side into the same cut out, an assembly kit
including a support side bracket and
supplementary sealings is available at our After
Sales Centres. The relevant installation instructions
are supplied within the kit package.
8
Fig. 3
REMOVE
FO 0548