Operating the Controller,
Operating a Station or Stations Manually
You can initiate one-time operation of a single
station or a combination of stations. If you run more
than one station, they will run in the order in which
they were selected.
To operate one station or multiple stations,
1. Rotate the dial to MANUAL WATERING.
The display shows the program, the station
number and any watering time remaining on that
station.
2. Press PGM
until the program using the
desired station is displayed.
3. Use the arrow keys to select the station you want
to operate.
4. Press MAN START/ADV
station.
5. If you want to operate more than one station,
repeat steps 2 through 4.
6. Return the dial to AUTO.
The stations operate in the sequence they were
selected. After the stations finish watering, the
controller returns to the automatic mode.
Note: If you are operating a station manually, you
cannot change the amount of time the station will
water. The controller will water the programmed
amount.
continued
to start the selected
Using the Test Program
This program allows you to run a test cycle for all
the stations on a particular program. You may select
how long the test will last.
To set and then start a test program,
1. Rotate the dial to OFF for 3 seconds, to cancel any
pending work. Otherwise the test program will be
executed after the automatic mode work finishes.
2. Rotate the dial to TEST/STATION DELAY
The display shows the program, TEST and the
length of time to test.
3. Press PGM
until the program you want to test
is displayed.
4. Use the arrow keys to set the length of time to test
each station, from one to 99 minutes.
5. Press MAN START/ADV
6. If you want to add other programs to the test, with
the dial set to TEST/STATION DELAY
press PGM
to select the program.
Then press MAN START/ ADV
program after the first one. You can stack four
programs.
Note: To cancel the test on all programs, rotate the
dial to OFF.
.
to start the test.
,
to stack the new
25