automatic gun.
■ Connect the round fan air to the
round fan air connection (R) [1-13] of
the automatic gun.
■ Insert material connection seal [3-3].
■ Connect the material supply to the
material connection [1-16] of the
automatic gun (optionally connect the
material flow to material flow connec-
tion [1-14] and material return to the
material return connection [1-15]).
8.2. Mounting on quick-
change fitting
■ Screw the spacers [4-1] and connec-
tor [4-2] into the nozzle head and gun
body.
■ Fit automatic gun on quick-change
fitting [4-3].
■ Guide the fastening screw [4-4]
through the quick-change fitting and
screw into the connector.
■ Fix the quick-change fitting to the fas-
tening system of the spraying system.
■ Connect control air to the quick-
change fitting.
■ Connect flat and round fan air to the
quick-change fitting.
■ Connect material supply to the quick-
change fitting (optionally connect
material flow connection and material
return connection to the quick-change
fitting with material return).
SATA ROB Automatic Gun Operating Instructions
8.3. Usage with material cir-
The following connection possi-
bilities are recommended when
using the automatic gun with
material circulation.
■ Insert a back-pressure regulator at
the material output.
■ The cross-section of the material
return pipe must be smaller than
the material feed pipe.
This ensures there is always
plenty of material in the fluid tip.
The material circulation keeps the
material used moving and it does
not come to a standstill.
The "nozzle head with material
circulation" variant of the automatic
gun can only be used with material
circulation. To this end the material
supply must be connected accord-
ingly (see chapter 8.1 and 8.2).
The "nozzle head with optional
material circulation" variant of the
automatic gun can also be used
with material circulation.
■ Disconnect the automatic gun from
the compressed air circuit and the
material supply.
■ Unscrew the dummy plug [5-1] from
the nozzle head.
■ Connect the circulation pipe with seal
to the material connection for material
circulation [5-2].
culation