Switching On The Electrical And Pneumatic Supply; Setting The Set Point - Aventics ED07 Instrucciones De Servicio

Válvula reguladora de presión
Ocultar thumbs Ver también para ED07:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 161
AVENTICS
The air exhaust port (port 3) (23) in the subbase may not be closed
with a screw.
Always install a suitable silencer (see "Accessories" on
page 76) or a line for restricted exhaust at the air exhaust port.
Outlet pressure –1 bar to +1 bar:
A vacuum must be connected at the air exhaust port (port 3) in
ED07 pressure regulators with a pressure range of –1 bar to
+1 bar.
7.2
Switching on the electrical and pneumatic
supply
Proceed as follows to commission the ED07 pressure regulator:
1. First switch on the pneumatic supply.
2. Then switch on the 24 V DC supply voltage.
7.3

Setting the set point

Enter the desired set point in the controller or potentiometer.
Observe the chapter "Selecting the correct supply pressure" on
page 65.
| ED07 | R41400766–BDL–001–AB
Commissioning the ED07 pressure regulator
63

Publicidad

Tabla de contenido
loading

Tabla de contenido