66
AVENTICS | CL03, CL03-XL | R402000141–BAL–001–AF
Assembly
5.2
Assembling the valve system
on the mounting surface
Risk of damage to the valve system!
Too long or too short screws, or too high torque, may damage
the threaded mounting holes.
To ensure correct assembly, use the correct screw
length and torque as follows:
– Torque (max.): 4 Nm
– Screw length (max.): 15 mm + t
– Screw length (min.): 9 mm + t
1)
t = thickness of mounting material
The dimensions of the complete valve system vary according
to the configuration.
1. See Fig. 3 and 4 for the dimensions for your valve system.
CAUTION
1)
1)