Diagnostic: Codes; Fault Codes - Stannah 60061700009 Manual De Instalación

Tabla de contenido

Publicidad

600 Diagnostic: Codes

GB
If '-','1' or '2' is shown in the Status Display window, removing the carriage cover and delatching
SW3 will show Fault Display LED's illuminated to indicate which options are fitted to the stairlift.
Status Display '1'or '2'
LED 1 On
Saxon chair
LED 2 On
LED 3
On - Powered footrest present
LED 4
On - Manual 2 way swivel.
If '3' is shown in the Status Display window, (Safety pad obstructed), removing the carriage
cover and delatching SW 3 will show Fault Display LED's illuminated to indicate which safety pad
may be obstructed on the stairlift.
Status Display '3'
LED 1 On Bottom footrest safety pad activated
LED 2
Not Assigned
LED 3 On Right footrest/interface safety pad activated
LED 4 On Right carriage safety pad activated
If '9' is displayed in the 'Status Display' window, refer to the following chart to identify the fault.
Status Display
9
A
Battery voltage below 23V. Carriage will operate from
1
carriage control buttons only.
Battery voltage below 21V (Carriage will NOT operate
2
from any controls)
5
Ultimate switch activated
6
OSG switch activated
7
Ultimate Line switch activated
1
Left and Right slowing switches activated simultaneously
2
Stop Switch activated before slowing switch
3
Dual calls from chair arm controls
4
Dual calls from remote controls
5
SL Chair: Seat raised and loaded simultaneously
6
'A' Circuit shorted to ground. (Chassis)
7
'B' Circuit shorted to ground. (Chassis)
1
No power supply detected to option PCB.
2
Battery voltage in excess of 30V.
3
Current limit exceeded 24A Instantaneous
4
Current limit exceeded 16A for 1 second
5
Powered swivel motor stalled
6
Powered swivel or footrest motor current limit exceeded
1
Brake not detected
2
Main motor not detected.
3
Footrest motor not detected
4
Swivel motor 1 not detected
5
Swivel motor 2 not detected
Main motor current drops below 1A when travelling
6
upwards
On
Off
Starla/Siena chair
Off
On

Fault Codes

FAULT
LED 5
On - Power swivel left allowed
SL chair
LED 6
On - Power swivel right allowed
LED 7
On = L/H stairlift Off = R/H stairlift
LED 8
On - Option PCB fitted
LED 5 On Bottom interface safety pad activated
LED 6
Not Assigned
LED 7 On Left footrest /interface safety pad activated
LED 8 On Left carriage safety pad activated.
Check Charger output / Replace Batteries
Check Charger output / Replace Batteries
Check for over travel / switch / wiring
Check OSG / switch / wiring loom
Check chair arm/ OSG / ultimate switches
or looms. Identified ULT 1- 4
Check switches / wiring loom
Check switch operation / connections
Check arm control / wiring loom
Check IR PCB connections
Check seat switches / loom
Identify and check 'A' wiring looms
Identify and check 'B' wiring looms
Check fuse F2 (3.15A)
Check charger output / motor
Excess load / Check Motor
Excess load / Check Motor
Excess load / Check connections
Excess load. Check options motors
Check brake and brake connections
Check main motor and connections
Check footrest motor and connections
Check swivel motor and connections
Check swivel motor and connections
Check motor connections / Check handing
plug if travelling downwards
ACTION