Avisos de fallo, alarma y del sistema
9.1 Avisos de fallo
Avisos de fallo de la unidad inversora
La siguiente tabla muestra los fallos de la unidad inversora que se visualizan en el Touch
Panel.
Tabla 9- 2
Avisos de fallo
Número de fallo Origen del fallo
11
Grid Monitoring
12
Grid Monitoring
13
Grid Monitoring
14
Grid Monitoring
15
Grid Monitoring
16
Grid Monitoring
17
Grid Monitoring
18
Grid Monitoring
19
Grid Monitoring
20
Grid Monitoring
21
Chopper Test
32
Peripheral faults
33
Peripheral faults
34
Peripheral faults
41
Plausibility Check
42
Plausibility Check
43
Plausibility Check
44
Plausibility Check
45
Plausibility Check
46
Plausibility Check
47
Plausibility Check
48
Plausibility Check
49
Plausibility Check
50
Plausibility Check
51
Plausibility Check
52
Plausibility Check
61
Feedback Monitoring
62
Feedback Monitoring
63
Feedback Monitoring
64
Feedback Monitoring
71
Sinamics Monitoring
72
Sinamics Monitoring
Acuse automático del fallo al cabo de 3 minutos.
1)
Acuse automático del fallo al cabo de 15 minutos.
2)
100
Texto del fallo
Line to Neutral low voltage trip
Line to Neutral high voltage trip
Line to Line low voltage trip
Line to Line high voltage trip
Low Frequency trip
High Frequency trip
Line to Line low filter voltage trip
Line to Line high filter voltage trip
Open phase condition detected
10 Minute overvoltage grid fault
Precharge resistor chopper test fault
Reactor temperature fault
Miniature circuit breaker blown
DC precharge resistor overtemperature
DC Link Current < DC Link Current Min
DC Link Current > DC Link Current Max
DC Current Input x < DC Current InputMin
DC Current Input x > DC Current InputMax
AC Current Phase x < AC Current PhaseMin
AC Current Phase x > AC Current PhaseMax
Supply Air Temp < Supply Air Temp Min
Supply Air Temp > Supply Air Temp Max
DC Input Currents > DC Link Current
DC Link Current > DC Input Currents
DC Voltage Input x < DC Voltage InputMin
DC Voltage Input x > DC Voltage InputMax
AC Contactor feedback fault
DC precharge resistor contactor 1
DC precharge resistor contactor 2
DC precharge resistor contactor 3
Sinamics power stack fault
Sinamics control unit fault
Instrucciones de servicio, 04/2011, A5E03467342-01
Acuse del fallo
Automático
1)
Automático
1)
Automático
1)
Automático
1)
Automático
1)
Automático
1)
Automático
1)
Automático
1)
Automático
1)
Automático
1)
Automático
1)
Automático
2)
Manual
Automático
1)
Automático
1)
Automático
1)
Automático
1)
Automático
1)
Automático
1)
Automático
1)
Automático
1)
Automático
1)
Automático
1)
Automático
1)
Automático
1)
Automático
1)
Manual
Manual
Manual
Manual
Automático
1)
Automático
1)
PVS500/PVS600