Operation
TO START THE HEATER
1. Fill the tank with paraffin until fuel gauge points to "F".
2. Be sure fuel cap is secure.
3. Plug power cord into electrical outlet.
4. Turn thermostat control knob to desired temperature setting
(70/125/175/215 only). The setting range is from 40 ° F to 110 °
F. Push the Power switch to the "ON" position. The power indi-
cator lamp and room temperature display (125/175/215 only)
will light and the heater will start.
Optimum pressure occurs when the nose cone is cherry red
and there are no extending flames from the heater.
NOTE: The room temperature display (125/175/215 only) will
indicate the following:
- When temperature is less than 0 ° F, display says "LO".
- When temperature is above 99 ° F, display says "HI".
- Between 0 ° and 99 ° F display shows actual temperature.
TO STOP THE HEATER:
turn the Power Switch to "OFF" position, and unplug the Power
Cord.
TO RESTART THE HEATER
1. Wait ten seconds after shutting off heater.
2. Turn the Power Switch to "ON" position.
3. Be sure to follow all starting procedure precautions.
LED operating time /
temp
Temp. setting
knob
Figure 2. To start the heater
STANLEY and
EN
:
Turn the Temp. Setting Knob to left,
On-Off switch
LED fuel gauge
are trademarks of Stanley Black & Decker, Inc or its affiliates and are used under
license by Pinnacle Products International, Inc - www.pinnacleint.com
LONG TERM STORAGE
Drain Fuel Tank
1. For models ST-45/70T-KFA-E, drain fuel through the fuel cap
opening using an approved siphon. For models ST-
125/175/215-KFA-E, drain fuel through the Drain Plug at the
bottom of the Fuel Tank.
2. To remove the Drain Plug (125/175/215), pull the Plug Grip
downward and remove seal head from drain hole in tank.
3. Rinse and completely empty the tank.
4. To replace, push the drain head fully into the drain hole and
secure by pushing the seal cap fully into the head hole.
IMPORTANT: Never store leftover fuel over the summer.
Using old fuel can damage your heater.
Store heater in a dry, well-ventilated area
Be sure that the storage area is free of dust and corrosive
vapors. Repack the heater in the original shipping material. Keep
the Users Manual in an easily accessible place.
Maintenance
Never service heater while it is plugged in or while hot!
FUEL/FUEL TANK:Flush every 200 hours of operation or as
needed with parafin.
AIR FILTERS:Filters should be replaced every 500 hours of
operation, or less, depending on conditions.
FAN BLADES:Blades should be cleaned at least once per heat-
ing season.
NOZZLES:Nozzles should be cleaned or replaced at least once
per heating season.
SPARK PLUG:Clean and re-gap every 600 hours of operation,
or replace as needed. Re-gap the terminals to 3.5mm.
PHOTOCELL:The Photocell should be cleaned at least once per
heating season or more depending on conditions.
Improper maintenance can lead to poor combustion and
soot production.
PUMP PRESSURE ADJUSTMENT:
While heater is operating, turn relief valve clockwise to increase,
counterclockwise to decrease. Use flat blade screwdriver to turn
valve. Correct pump pressure is as follows:
Model #
ST-45-KFA-E
ST-70T-KFA-E
ST-125T-KFA-E
ST-175T-KFA-E
ST-215T-KFA-E
Pump Pressure
3.0 PSI / 0.21 BAR
3.7 PSI / 0.26 BAR
4.5 PSI / 0.31 BAR
6.5 PSI / 0.45 BAR
8.0 PSI / 0.55 BAR