Section 5 − Selecting And Preparing Tungsten Electrode For Dc Or Ac Welding; Selecting Tungsten Electrode (Wear Clean Gloves To Prevent Contamination Of Tungsten) - Miller Diamondback Serie Manual Del Operador

Ocultar thumbs Ver también para Diamondback Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SECTION 5 − SELECTING AND PREPARING TUNGSTEN
ELECTRODE FOR DC OR AC WELDING
Y Whenever possible and practical, use DC weld output instead of AC weld output.
5-1. Selecting Tungsten Electrode (
Electrode Diameter
2% Ceria (Orange Band), 1.5% Lan-
thanum (Gray Band), Or 2% Thorium
(Red Band) Alloy Tungstens
.010"
.020"
.040"
1/16"
3/32"
1/8"
5/32"
3/16"
1/4"
Pure Tungsten
(Green Band)
.010"
.020"
.040"
1/16"
3/32"
1/8"
5/32"
3/16"
1/4"
Zirconium Alloyed Tungsten (Brown
Band)
.010"
.020"
.040"
1/16"
3/32"
1/8"
5/32"
3/16"
1/4"
Typical argon shielding gas flow rates are 15 to 35 cfh (cubic feet per hour).
Figures listed are a guide and are a composite of recommendations from American Welding Society (AWS) and electrode manufacturers.
Wear Clean gloves To Prevent Contamination Of Tungsten
Amperage Range - Gas Type
DC − Argon − Electrode
DC − Argon − Elec-
Negative/Straight Po-
trode Positive/Rev-
larity
erse Polarity
Up to 25
15-40
25-85
50-160
135-235
250-400
400-500
500-750
750-1000
Up to 15
5-20
15-80
70-150
125-225
225-360
360-450
450-720
720-950
*
*
*
*
*
*
*
*
*
Return To Table Of Contents
- Polarity
AC − Argon
*
Up to 20
*
15-35
*
20-80
10-20
50-150
15-30
130-250
25-40
225-360
40-55
300-450
55-80
400-500
80-125
600-800
*
Up to 15
*
5-20
*
10-60
10-20
50-100
15-30
100-160
25-40
150-210
40-55
200-275
55-80
250-350
80-125
325-450
*
Up to 20
*
15-35
*
20-80
*
50-150
*
130-250
*
225-360
*
300-450
*
400-550
*
600-800
*Not Recommended.
ac/dc_gtaw 2/2004
)
AC − Argon −
Balanced Wave
Up to 15
5-20
20-60
60-120
100-180
160-250
200-320
290-390
340-525
Up to 10
10-20
20-30
30-80
60-130
100-180
160-240
190-300
250-400
Up to 15
5-20
20-60
60-120
100-180
160-250
200-320
290-390
340-525
OM-1600 Page 9

Publicidad

Tabla de contenido
loading

Tabla de contenido