Descargar Imprimir esta página

Technical Data; Maximum Operating Pressure - Pentair PVM Serie Instrucciones De Funcionamiento

Ocultar thumbs Ver también para PVM Serie:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
CHAPTER 4

TECHNICAL DATA

T [°C]
20
30
40
K
[m]
0,2
0,4
0,8
T
H [m]
0
500
1000
K
[m]
0
0,55
1,10
H
4.1 TEMPERATURES
Ambient temperature: 0°C to +50°C
WARNING
If ambient temperature is above +50 degrees C, or if the pump is located at elevations more than 1,000 meters above sea level,
the motor' s output must be decreased to compensate for less effective cooling, and may have to be replaced with a larger motor.
Liquid temperature: -15°C to +120°C

4.2 MAXIMUM OPERATING PRESSURE

See appendix
50
60
70
80
1,3
2,2
3,3
5,0
1500
2000
2500
3000
1,65
2,20
2,75
3,30
90
100
110
120
7,4
11
15
22
EN
ORIGINAL INSTRUCTION
3

Publicidad

Capítulos

loading