Resetting Default Volumes
To reset the machine to the default 1 CUP
and 2 CUP shot volumes, press and hold the
PROGRAM button until the machine beeps
three times. Release the PROGRAM button.
The machine will return to its original default
volume settings and default espresso water
temperature (see 'Advanced Temperature
Mode', page 17).
NOTE
Default settings: 1 CUP shot volume is approx.
1oz / 30ml. 2 CUP shot volume is approx.
2oz / 60ml.
Manual Shot Volume
Manually control low pressure pre-infusion
time and shot volume without re-programming
the presets shot volume.
Press and hold the 1 CUP or 2 CUP button.
The extraction will enter low pressure
pre-infusion until the button is released.
When the 1 CUP or 2 CUP button is released,
extraction will continue at full pressure.
Press the 1 CUP or 2 CUP button again
once the desired volume of espresso has
been extracted.
PROGRAM
PRESS & HOLD
NOTE
For optimal flavor when using a 1 CUP filter
basket, you should extract approx. 1oz / 30ml.
When using a 2 CUP filter basket, you should
extract approx. 2oz / 60ml.
ESPRESSO PRESSURE GAUGE
Low Pressure Pre-Infusion
The gauge needle will be positioned in the
pre-infusion zone at the start of the extraction
indicating the machine is in low pressure pre-
infusion mode. The low pressure pre-infusion
gradually increases water pressure to gently
expand grinds for an even extraction before
increasing to full pressure.
Ideal Espresso Zone
The gauge needle, when positioned anywhere
within the solid grey zone during extraction,
indicates the espresso has been extracted at
the ideal pressure.
Under Extracted Zone
The gauge needle, when positioned in the
lower zone during extraction, indicates the
espresso has been extracted with
insufficient pressure.