ЗАО "Берг АБ"
(495) 727-22-72
7. Troubleshooting
Display
E03 E
E05 E
E06 E
E10E
E11E
E12E
8. Spare parts
Designation
TIH L-PMV
TIH L-PLV
TIH L44-Y15
TIH L44-Y10
TIH L77-Y15
TIH CP
TIH RC2
TIH CB50A
TIH CB100A
TIH P20
SKF TIH L
Fault
Overheated coil
Temperature increase of less
than 1°C (1.8°F) every 1 minute
(or every 2 minutes)
Temperature probe not
connected (or defective) or
excessive temperature drop.
Electronics communication
problem
Electronics communication
problem
Electronics communication
problem
Description
Power print 400-460V, 50-60 Hz
Power print 200-240V, 50-60 Hz
Yoke 100x100 mm cross section (3,9 x 3,9 in), complete with
sliding rails for TIH L44 heater type
Yoke 70x70 mm cross section (2,7x2,7 in) complete with
handles for TIH L44 heater type
Yoke 100x100mm cross section (3,9 x 3,9 in), complete with
sliding rails for TIH L77 heater type
Control print
Remote control for TIH L type
Circuit breaker 50A for TIH Lxx/MV
Circuit breaker 100A for TIH Lxx/LV
Temperature probe K type incl. cable and plug
promshop- biz@ya.ru
Action
Wait until the induction coil cools.
Switch the heater OFF and then back
ON.
Check the temperature probe
connection. If the connection is OK,
select the 2 minutes interval as
described in section 6 or operate the
heater in TIME MODE.
Check the temperature probe.
Switch the heater OFF and then back
ON. If problem remains return the TIH
to SKF for repair.
Switch the heater OFF and then back
ON. If problem remains return the TIH
to SKF for repair.
Switch the heater OFF and then back
ON. If problem remains return the TIH
to SKF for repair.
www.promshop.biz
13