Safety Features; Troubleshooting - SKF TIH 030m Instrucciones De Uso

Ocultar thumbs Ver también para TIH 030m:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 40
6

SAFETY FEATURES

The TIH 030m is equipped with the following safety features:
• Automatic overheating protection
• Automatic current control
• Over-current circuit breaker.
• In the TEMP MODE the heater will switch off if the temperature probe does not
register a temperature increase of 1°C (1.8°F) every 15 seconds (0.25 minute).
To increase the interval to 30 seconds (0.50 minute), press MODE and DOWN
at the same time.
7

TROUBLESHOOTING

A system fault will be indicated by an acoustic signal and one of the following fault
codes on the remote control display:
Display Fault
E03 E
Overheated coil
E05 E
Temperature increase of
less than 1°C (1.8°F) every
15 seconds (or 1° every 30
seconds)
E06 E
Temperature probe not
connected (or defective) or
excessive temperature
drop.
E10E
Electronics communication
problem
E11E
Electronics communication
problem
E12E
Electronics communication
problem
14
Action
Wait until the inductive coil cools. Switch the heater
OFF and then back ON.
Check the temperature probe connection.
If the connection is OK, select the 30 second interval
as described in section 6 or operate the heater in
TIME MODE.
Check the temperature probe.
Switch the heater OFF and then back ON.
If problem remains return the TIH to SKF for repair.
Switch the heater OFF and then back ON.
If problem remains return the TIH to SKF for repair.
Switch the heater OFF and then back ON.
If problem remains return the TIH to SKF for repair.
SKF TIH 030m

Publicidad

Tabla de contenido
loading

Tabla de contenido