SATAjet 3000 K (RP/HVLP) Operating Instructions
Adjusting the material flow rate
Information!
When painting use only the quantity of material required for the work
step.
Maintain the necessary spray distance when painting. Store or dispose
of the material properly after painting.
Information!
There will be less wear on the paint nozzle and paint needle if the ma-
terial flow control is fully open. Select the nozzle size depending on the
spray medium and working speed.
The quantity of material and thus the needle lift can be variably adjusted
using the adjustment screw as shown in figures [4-1], [4-2], [4-3] and
[4-4].
■ Loosen counter nut [1-3].
■ Pull trigger [1-10] all the way off.
■ Adjust material flow rate using adjustment screw [1-2].
■ Tighten counter nut by hand.
■ Pull trigger [6-2] all the way and adjust the material supply pressure.
Adjustment of the Spray Fan Pattern
The spray jet can be variably adjusted using round / flat fan control [1-1]
until a round fan pattern is produced.
■ The fan pattern can be set by turning the round/flat fan control [1-1].
■ Turn right [5-2] – round fan pattern
■ Turn left [5-1] – flat fan pattern
Starting to paint
■ Maintain spray distance (see Chapter 7).
■ Squeeze trigger all the way [6-2] and operate paint spray gun 90° to
the surface to be painted [6-1].
■ Provide for spray air supply and material supply.
■ Pull back on trigger [1-10] and start painting. Readjust the material flow
rate and fan pattern as needed.
Completing the painting operation
■ Move the trigger [1-10] to the start position.
■ When done painting, cut off the atomizing air. Read and follow the infor-
mation on care and storage (see 10).