Heater installation measurements
NOTE ! All the measurements given are in millimetres!
All the measures are minimum distances unless otherwise stated!
Try to rotate the heater and the rotating ring so that the handle when opening the lid
does not contact the wall.
The lid must not direct the steam or hot air directly to the wall or some other obstacle.
Corner installation
Control panel installation
50
OK
Connecting the heater to the mains
Power
Sauna room *)
Volume
Height
kW
m
mm
3
min max
min
4,5
5 - 8
1900
6,5
7 - 13
1900
9,6
10 - 18
1900
*) NOTE! All the capacity measurements have been calculated for fully
heat-insulated saunas.
All reserving heaters, such as Rondo, require a fully heat-insulated sauna.
The insulation has a critical effect on the functioning of the sauna.
400
10
Installation in the
middle of the
seating boards
The main switch and the
overheating limiter reset
Heater connection
Fixed installation
cable
H07RN-F
mm
2
5 x 1,5
5 x 1,5
5 x 2,5
The main switch and the overheating
limiter reset
Fixing of the heater
to the floor. NOTE!
Fixing from two
(2) of the legs.
Fuse
mm
2
A
5 x 1,5
3 x 10
5 x 1,5
3 x 10
5 x 2,5
3 x 16
Heater leg
Floor fixing
skrew
Fixing iron
Adjustable
leg
9