Electronic Circuit Board; Serial Port; Backup Battery - EdilKamin IDROSALLY Instalación Uso Y Mantenimiento

Termoestufa de pellet
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 92

• ELECTRONIC CIRCUIT BOARD

LEONARDO is a combustion safety and control system which allows optimal performan-
ce in all conditions thanks to two sensors measuring the pressure level in the combustion
chamber and smoke temperature. The detection of and subsequent optimisation of these
two parameters is continuous in order to correct operation anomalies in real time.
The LEONARDO system offers constant combustion, automatically regulating the draft
based on the characteristics of the chimney ue (bends, length, shape, diameter, etc..) and
environmental conditions (wind, humidity, atmospheric pressure, installations at high al-
titude, etc.). The standards for installation must be respected. LEONARDO system is also
able to recognise the type of pellets and automatically djust the ow moment by moment
to ensure the required level of combustion.
• ELECTRONIC CIRCUIT BOARD
Emergency button
socket
RS323
remote-control
device
Smoke expulsion motor

SERIAL PORT

The Dealer can install an optional on the AUX outlet for controlling the process of
switching on and off (e.g. telephone remote, local thermostat), located at the rear oh the
boiler-stove. Can be connected via special optional trestle (code 640560).

BACKUP BATTERY

A backup battery is found on the control board (3-Volt CR 2032 battery).
Its malfunction is indicated with the following messages (not considered a defect but
due to normal wear-and-tear): "Battery check".
For more detailed information, please contact the DEALER who has performed the rst
1st ignition.
GENERAL INFORMATION
Water outlet
probe
ow sensor
smoke rpm
screw rpm
Vacuum gauge
thermocouple
backup battery
lithium CR2032
fuse 2A
M SCREW
Outlet pump
Vacuum gauge
Reading
points
ventilation
230 vac power supply
fuse 2A
50Hz +/-10%
PORT BACK STOVE
FUSE two fuses are inserted in the so-
cket with switch, located on the back of
the boiler-stove, one of which operational
(*) and the other is held in reserve (* *).
- 36
-
*
* patented
* **

Publicidad

Tabla de contenido
loading

Tabla de contenido