ELECTRONIC CIRCUIT BOARD

CONSOLLE cod. 297240
Panel control
SMOKE
EXPULSION
MOTOR

SERIAL PORT

The Dealer can install an optional on the AUX outlet
for controlling the process of switching on and off
(e.g. telephone remote, local thermostat), located at the
rear oh the stove. Can be connected via special optio-
nal trestle (code 621240).

BACKUP BATTERY

A backup battery is found on the control board (3-Volt
CR 2032 battery). Its malfunction is indicated with the
following messages: (not considered a defect but due
to normal wear-and-tear): "Battery Check".
For more detailed information, please contact the
DEALER who has performed the first 1st ignition.
FEATURES
AUX
Service
Li t hi um
backup battery
+
C R2032
SCREW
VENTILATION
AMBIENT
FLOW SENSOR
SMOKE RPM
230 Vac POWER
SUPPLY
50Hz +/-10%
PORT BACK STOVE
FUSE
*
two fuses are inserted in the socket with switch,
located on the back of the stove, one of which
operational and the other is held in reserve.
34
SENSOR AIR AMBIENT
Vacuum gauge
Reading points
2A FUSE
* *