9.

ALARM SIGNALS

9.1
List of alarms
Anomalies are shown on Display 2 during operation, see the description:
P1NO - Chamber probe alarm: temperature probe broken or cut off.
P7NO - Board temperature alarm: board overheated (over 70° C).
MOT - Motor alarm: motor overheated.
EEP: incorrect software load/update.
FLAM: no flame.
VENT - Vent alarm: venting device malfunction.
OFF RUN alarm: fan device malfunction.
Press "PLUS" (Fig 2/D) for 5 seconds to temporarily shut off the alarm. The
message will reoccur until resolution of the problem.
Contact the authorised service centre.
The authorised technician will identify the cause of the problem
and restore proper operation.
TROUBLESHOOTING
Whenever the appliance does not work properly, try to solve the less serious problems using
this table.
ANOMALY
The appliance does not turn on.
The inner walls are covered with
limescale.
The cooking compartment is
stained.
The gas appliance will not turn on
No water
Electronic components overheating
(Alarm board temperature)
"Filter Cleaning" Message
If the problem cannot be resolved, turn the appliance off and shut all the supply valves. Then
contact customer service.
THE PRESENT MANUAL IS PROPERT Y OF THE MANUFACTURER. ANY REPRODUCTION, EVEN PARTIAL, IS PROHIBITED.
POSSIBLE CAUSE
The master switch is not con-
nected.
The circuit breaker or magnetic
circuit breaker has tripped
The water softener is not con-
nected or is empty
Quality of the water.
Ineffective detergent.
Insufficient rinsing.
• Gas valve closed.
• Air in the hose
The water tap is closed
Cooling fans obstructed
Filter maintenance timer expired
- 18 -
18
Display 3
Display 1
Display 2
INTERVENTION
Connect the master switch.
Reset the circuit breaker or ma-
gnetic circuit breaker
Connect the appliance to a wa-
ter softener.
Regenerate the water softener.
Descale the cooking com-
partment.
Filter the water (see water sof-
tener).
Use the recommended detergent.
Rinse once again.
• Open the gas valve
• Repeat the operation
Open the water tap
Free the air passage or clean the
filters
Proceed with cleaning (see 8.4
Periodic inspections to perform)
D
Fig.1

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cyg serieCye6Cye102Cyg10Cye10Cyg6

Tabla de contenido