THERMIC CAPACITY
G
L
OPERATION
I
NOx EMMISION
S
MOTOR
H
ABSORBED ELECTRICAL POWER*
line fuse
IGNITION TRANSFORMER
VOLTAGE
PROTECTION RATING
FLAME DETECTOR
NOISE**
WEIGHT
Natural Gas (G 20)
FLOW RATE
GAS PRESSURE
*)
Total absorption at start with ignition transformer on. .
**) Noise levels measured by the manufacturer in the laboratory with burner running on test boiler, at maximum nominal thermal output.
STANDARD ACCESSORIES
BURNER FIXING FLANGE
ISOLATING GASKET
STUD BOLTS
EXAGONAL NUTS
FLAT WASHERS

TECHNICAL DATA

MAX kW
mg/kWh
A / 400 V
MAX
MIN
MAX
0006081370_201107
TBG 45ME
450
MIN kW
100
Progressive/modulating two-stage
< 80 (Classe III secondo EN 676)
kW
0,50
r.p.m.
2730
kW
0,70
- -
26 kV - 40 mA - 230/240 V - 50/60 Hz
1N ~ 230 V ± 10%- 50
Hz
IP 40
IONIZATION PROBE
dBA
73
kg
40
m³n/h
45,3
m³n/h
10,1
mbar
500
TBG 45ME
2
1
N° 4 M 12
N° 4 M 12
N° 4 Ø 12
4 / 16
TBG 60ME
600
120
0,75
2800
0,97
4
3N ~ 400 V ±10%- 50
Hz
75
42
60,3
12,1
TBG 60ME
2
1
N° 4 M 12
N° 4 M 12
N° 4 Ø 12