Extel TELIA Instrucciones De Uso página 105

Ocultar thumbs Ver también para TELIA:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 54
- An electronic control unit that provides power supply to the intercom panel (fig.1-10) containing the radio
transceiver and batteries (not included).
The base station (fig. 1.1) is required to be installed even if the phone function is not used.
CAUTION !
Do not the block the 2 ventilation holes (fig.6.a-T) at the bottom of the electronics control unit.
Allow for a silicone gasket (fig.6.a-J) on the upper half of the intercom panel frame.
(To avoid condensation, the gasket shall be placed on the upper half of the visor (fig. 6.d-J)).
• Installing the electronic control unit (fig. 6.b)
1 6-core cable (E) and 2 wires (F) are attached to the control unit. The cable for connecting the door station must
pass through a hole through the pillar (it is necessary to pierce the pillar or wall accordingly).
The other 2 wires (F) (one red and one black) must then
Once the ideal location has been determined:
1 • Remove the top cover of the control unti by unscrewing the 6 Phillips head screws (fig. 6h-H)
CAUTION !
Never touch the electronic circuit directly.
In any case, you should not insert the batteries before completing the installation
2 • Secure the control unit using two screws through the two holes (K) at the top and bottom (fig. 6-e)
3 • First pass the connection cable to the intercom panel through the hole in the pillar
(Fig. 6-a)
• Installing the intercom panel (Fig. 6c)
Tip: ensure the cables (the intercom panel cable and the electric door opener cable) are covered with a protec-
tive sheathing to protect them from weather and impact damage.
Do not cut the excess off the 6-core cable, to avoid oxidation problems and loose connections. Wind it between
the pillar and the electronic control unit (fig. 6a).
1) Unscrew the Phillips screw (A)
2) Tilt the plate (B) forward and disengage it from the bottom
3) Put a silicone gasket on the back of the visor to avoid infiltration flowing along the wall (Fig. 6.d-J).
4) Using the three screws ( F), fix the visor (C) close to the wall, so that the hole (D) is opposite the cable (E).
5) Guide the connection cable through.
6) Connect the 6 wires (E) to the rear of the plate (FIG. 2b):
M- white
M+ grey
7) Reassemble the plate, tighten the screw (A)
To complete the installation of the outer part, insert four 1.5 V- LR 20 type alkaline batteries in the battery
compartment in the electronic control unit, after tilting the trap be sure to respect the polarity (Fig. 6.f)
• Connecting an automated system and a lock/gasket on the electronic control unit
Connect your gasket and your automated system as displayed in the diagram (Fig. 6.g). There is no
polarity for door opener connections.
• Sound settings (fig. 6g)
Set the volume by pressing the button ( A: Adjusting the volume of the intercom panel or B: Adjusting
the volume of the handset). Pressing the button increases the volume each time. Space the pulses
by 1 second.
5 different levels from low to high:
be connected to the lock or to the electric door opener.
S-
pink
S+ purple
C- black
C+ red
GB6

Publicidad

Tabla de contenido
loading

Tabla de contenido