Connections With A Flexpdu Module; Ups Connection - Eaton Pulsar Serie Manual De Instalación Y De Usuario

Ocultar thumbs Ver también para Pulsar Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2.6
Connections with a FlexPDU (Power Distribution Unit) module (optional)
45
2.7

UPS Connection

i
Check that the indications on the rear panel of the silkscreen of the UPS correspond to the AC-power source and the
true electrical source of the required load.
Tower model
RT model
Note. The UPS charges the battery as soon as it is connected to the AC-power source, even if button (27) is not pressed.
i
Once the UPS is connected to the AC-power source, eight hours of charging are required before the battery can supply
the rated backup time.
7
8
9
46
48
1. Connect the UPS socket (9) to the AC-power
source using the power cable from the equip-
ments to be protected.
2. Connect the input socket on the FlexPDU
module (48) to the UPS outlet (7) or (8). The
cable and the connectors are marked in red.
3. Connect the equipment to the outlets (45)
and (46) on the FlexPDU module. These
outlets differ, depending on the version of the
FlexPDU module.
1. Connect the input plug (9) to the AC power
source using the power cable from the equip-
ments to be protected.
2. Connect the loads to the UPS.
It is preferable to connect the priority loads to the
outlets marked (8) and the non-priority loads to
the outlets marked (7) that can be programmed in
pairs (1 and 2). To program the outlets, the EATON
communications software is required.
86-86700-00EN A02 - Page 15