Additional Thermostat; Installation Of Additional Thermostat; Delta T; First Load - Dal Zotto Leyla Elite Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ADDITIONAL THERMOSTAT

N.B. : THE INSTALLATION MUST BE PERFORMED BY AN AUTHORISED TECHNICIAN
There is a possibility to thermostat a room adjacent to the room where the stove has been placed; simply connect a thermostat following
the procedure described in the following section (it is advisable to place the optional mechanical thermostat at a heigh from the ground
equal to 1.50 m). Stove operation with the external thermostat connected in the TA terminal can be di erent depending on the activation or
deactivation of the STAND BY function.

INSTALLATION OF ADDITIONAL THERMOSTAT

Š Turn o the appliance via the main switch on the back of the
stove.
Š Remove the plug from the power outlet.
Š Connect the two cables of the thermostat on the terminal (TA)
behind the machine.
FOR CORRECT OPERATION, SET THE SET ROOM
THERMOSTAT TO LOW TA

DELTA T

This function allows you to set the hysteresis to switch the stove on and o DELTA T, used as a room temperature adjustment interval if not
managed by an external thermostat. The exact temperature for ignition is SET THERMOSTAT DELTA T. The temperature for switch-o is SET
THERMOSTAT + DELTA T.
The possible values for DELTA T go from: 0.5 - 5°C
CONTROLS PROCEDURE
Š Press 6.
Š Press 3 until SETTINGS appears and con rm by pressing 6.
Š Press 3 until DELTA T appears and con rm by pressing 6.
Š Use keys 4 -5 to set the desired value.
Š Press 6 to con rm or 1 to return to the previous menus to the initial state.

FIRST LOAD

This function allows to ll the auger, facilitating the rst start-up phases of the stove, or in the event that the pellet hopper is empty. With the
stove cold and "OFF", make sure the pellet has been introduced inside the tank and activate the FIRST LOAD function, con rming with OK.
To stop the continuous loading, simply press 1 for 3 seconds.
CONTROLS PROCEDURE
Š Press 6.
Š Press 3 until SETTINGS appears and con rm by pressing 6.
Š Keep pressing 3 until FIRST LOAD appears and con rm by pressing 6.
Š Use keys 4-5 to enable "ON" / disable "OFF"
Š Press 1 several times to con rm and exit the menu.

RESET

It allows you to bring all the values that can be changed by the user back to the factory settings.
CONTROLS PROCEDURE
Š Press 6.
Š Press 3 until SETTINGS appears and con rm by pressing 6.
Š Keep pressing 3 until STAND BY appears and con rm by pressing 6.
Š Use keys 4-5 to enable "ON" / disable "OFF"
Š Press 1 several times to con rm and exit the menu.
58
ENGLISH

Publicidad

Tabla de contenido
loading

Tabla de contenido