Connect the appliance to the mains electricity sup-
ply as follows.
2 - Remove the knob (C).
3 - Undo the screws (D) and remove the control
panel (E).
4 - Undo the screws (F) to remove the lid (G).
5 - Connect the circuit-breaker (A) to the terminal
board (H) of the appliance as shown in the dia-
IT
gram and in the electrical system diagram at
the back of the manual.
GB
Use a flexible cable with at least type H07RN-F
characteristics, rated for an operating tempera-
DE
ture of at least 80°C.
6 - Tighten the cable gland (L).
FR
Important
When connecting, take care to connect the
ES
neutral and earth lines.
NL
CONVERSION OF ELECTRICITY SUPPLY (191BR1E - 191BR2E - 191BR3E)
The appliance is supplied at an operating voltage
400V/3N (indicated on the sticker applied to the da-
taplate); conversion to 230V/3 can be carried out as
described below.
English
1 - If not already present, install a circuit-breaker
(A) with overload cutout and differential safety
breaker close to the appliance.
A
D
C
F
7 - Fit the lid (G) and secure it with the screw (F).
8 - Replace the control panel (E) and the knob (C)
on completion of the operation.
Before doing any work, cut off the mains elec-
tricity supply.
- 18 -
E
D
G
H
L
Caution - warning
IDM-39616301200.tif
IDM-39616301300.tif