Maintenance
4.2.1
Cleaning and disinfecting procedure
1. Remove any accessories from the facepiece and clean them sep-
1)
arately
.
2. Clean all parts with lukewarm water and 1008 GREEN LIQUID
HAND DISH WASH using a soft cloth.
3. Thoroughly rinse all parts under running water.
4. Prepare a disinfectant bath containing water and 800 SPUR-TEX
Disinfectant (max. temperature: 86 °F/30 °C, concentration:
2 fl.oz. per 1 gallon/60 ml per 3.79 l).
5. Place all parts to be disinfected into the disinfectant bath (duration:
15 minutes).
6. Thoroughly rinse all parts under running water.
7. Dry all parts in the air or in a drying cabinet (max. temperature:
140 °F/60 °C). Do not expose to direct sunlight. Do not shake the
facepiece in order to remove water.
8. Mount the accessories if necessary.
4.2.2

Alternative cleaning and disinfecting procedure

1. Remove any accessories from the facepiece and clean them
separately
2. Prepare a cleaning solution containing water and NEUTRAL
DISINFECTANT CLEANER (max. temperature 86 °F/30 °C,
concentration: 1 fl. oz. per 2 gallons/30 ml per 7.57 l).
3. Immerse the facepiece in the solution (duration: 10 minutes).
Make sure that all parts are wetted.
4. Thoroughly rinse all parts under running water.
5. Dry all parts in the air or in a drying cabinet (max. temperature:
140 °F/60 °C). Do not expose to direct sunlight. Do not shake the
facepiece in order to remove water.
6. Mount the accessories if necessary.
1)
Strictly follow the corresponding Instructions for Use.
2)
Strictly follow the corresponding Instructions for Use.