3. Operating instructions

Remove the container plug under the pump
handle to check the oil level.
Make sure there is suficient oil to complete the
operation. Use oil with a viscosity at operating
temperature of 300 mm
mount bearings with the SKF Oil Injection
Method or a hydraulic nut. Use oil with a
viscosity at operating temperature of 900 mm
(4 100 SUS) for dismounting bearings.
Hold the pump in a horizontal position and
tilt forward as necessary to make sure the oil
supply is constant.
Screw the quick connection nipple (G
into the workpiece.
A.
Pump
B.
Release
6
EN
EN
/s (1 400 SUS) to
2
/s
2
/
) tightly
1
4
Connect the hose to the quick connection nipple.
To connect or disconnect the hose you must
retract the collar on the quick connector. Do not
disconnect the hose while the oil is pressurised.
Move the release valve to the pump position.
Do not tighten the valve too much. The release
valve is found on the side of the pump.
Operate the pump until the pressure increases
to the level necessary for your application.
When the pressure is more than 150 MPa
(21 750 psi), the safety valve will open.
Last, open the release valve to let the oil low
back to the oil container.