3. Operating instructions

a) Check oil level by unthreading the container
plug on top of the square container.
Make sure there is enough of oil for your
complete operation. For mounting bearings with
the SKF Oil Injection Method, or by means of an
hydraulic nut, it is recommended to use an oil
with a viscosity of approximately 300 mm
(1 400 SUS) at the operating temperature. For
dismounting bearings, we recommend to use
an oil with a viscosity around 900 mm
(4 100 SUS) at operating temperature.
b) Hold the pump horizontally or slightly tilted
forwards in order to secure oil supply.
A.
Filter plug
B.
Handle block pin
C.
Pressure gauge connection
D.
Oil release valve
2
/s
2
/s
A
D
c)
Close the release valve on the right hand side of
the pump without using force.
d) Screw the quick connection nipple (G
the application.
e) Connect the hose to the nipple by gently
withdrawing the snap-ring on the quick
connector. The hose is disconnected in the same
manner.
f)
Continue pumping until necessary pressure is
reached for your application. Maximum pressure
is 50 MPa (7 250 psi) at which pressure the
safety valve will open.
g) Open the release valve, allowing superfluous oil
to return to the oil container.