3. Operating instructions
a) Check oil level by unthreading the container
plug on the rear end of the container. Make
sure there is enough of oil for your complete
operation.
For mounting bearings with the SKF oil injection
method, or by means of an hydraulic nut, it
is recommended to use an oil with a viscosity
of approximately 300 mm
the operating temperature. For dismounting
bearings, we recommend to use an oil with a
viscosity of approx 900 mm
operating temperature.
b) Hold the pump horizontally or slightly tilted
forwards in order to secure oil supply.
A
A.
Oil release valve
B.
Pressure gauge
/s (1 400 SUS) at
2
/s (4 100 SUS) at
2
c)
Close the release valve on the right hand side of
the pump without using force.
d) Screw the quick connection nipple (G
the application.
e) Connect the hose to the nipple by gently
withdrawing the snap-ring on the quick
connector. The hose is disconnected in the
same manner.
f ) Continue pumping until necessary pressure is
reached for your application. Maximum pressure
is 100 MPa (14 500 psi) at which pressure the
safety valve will open.
g) Open the release valve, allowing superluous oil
to return to the oil container.