Ingeteam
11. Using the unit
The inverter operation management is done through the control panel and/or web
application.
For simple tasks, the control panel made up of two buttons and their
corresponding LEDs can be used.
The full management is carried out through a web application.
11.1. Control panel
11.1.1. Buttons
The control panel has two buttons:
On/Off switch. Changes the status of the inverter from off to on and vice versa. The press must last
longer than one second.
Wi-Fi button. It resets the communication or restores it to factory settings.
Both buttons are also available in the web application, with the same functionalities.
11.1.2. LED
The operating logic of the two LEDs is described below:
LED On/Off
•
Flashing green: attempting to connect or reconnect to the electricity grid.
•
Fixed green: inverter connected to the electricity grid. The inverter remains connected to
the grid without any active incident.
•
Alternating fixed green-flashing red: inverter connected to the electricity grid, with an active
incident. See more information about the warning via the web application.
•
Flashing red: inverter disconnected from the electricity grid due to an active incident. See
more information about the warning via the web application.
•
Fixed red: inverter disconnected from the electricity grid due to a manual stop.
Wi-Fi LED
•
Off: Wi-Fi disabled.
•
Blue flashing slowly: inverter operating in Access Point mode. The inverter works as an
access point, creating a Wi-Fi network. In this mode it is not possible to connect to a Wi-Fi
network.
•
Flashing blue: connected to a Wi-Fi network (inverter in client mode).
•
Blue flashing quickly: the inverter is trying to connect to a Wi-Fi network.
The logic of both LEDs is the same as in the web application.
96
ABS2011IQM01_D - Installation and Operation Manual
Using the unit
Control panel