Installing the unit

6. Installing the unit
Before installing the unit, you must remove the packaging, taking special care not to damage the housing.
Check that there is no condensation inside the packaging. If there are signs of condensation, the unit must not be
installed until you are sure it is completely dry.
All installation operations must comply with current regulations.
All operations involving moving heavy weights must be carried out by two people.

6.1. General requirements for installation

The environment of the unit must be appropriate and meet the guidelines described in Chapter "5.
Preparation for installing the unit". Additionally, the parts used in the rest of the installation must be
compatible with the unit and comply with the applicable legislation.
Ventilation and the space for work must be suitable for maintenance tasks according to the applicable
regulations in force.
The external connection devices must be suitable and sufficiently close as set forth in current regulations.
The feed cables must be of the appropriate gage for the maximum current.
You must take special care to ensure that there are no external elements near the air inlets and outlets
that obstruct proper cooling of the unit.

6.2. Attaching the unit to the wall

These inverters can be installed together with a connections box. If using the connections box
provided by Ingeteam, it may installed annexed to the lower part of the inverter or separated from it.
If you want to install the connections box annexed to the lower part of the inverter, see the
installations manual for the connections box to proceed with the installation of the inverter-
connections box group, and do not follow the instructions below.
If you want to install the connections box separate from the inverter, follow the instructions below to
install the inverter, and see the connections box installation manual for installing the latter.
If you do not want to install a connections box, follow the instructions described below to install the
inverter.
These units have a system for securing them to the wall using a plate. The steps for fixing the unit properly are as
follows. The weight of the unit must be taken into account.
The top attachment plate for the unit supports the weight. The bottom point fixes the inverter to the wall and
prevents vibrations.