Technical Data - Leuze electronic BCL 900i Manual De Usuario

Lector de codigo de barras
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20

Technical data

NOTICE
Technical data
 Additional specifications and notices for using the device can be found in the
operating instructions.
1)
Operating voltage
Current consumption
Light source / Wavelength
Laser class
Scanning rate
Reading distance
Resolution
Code types
Interface type
Auxiliary interface
Switching inputs
Switching outputs
Degree of protection
VDE safety class
Housing
Weight
Dimensions
Ambient temp.
Rel. air humidity (non-condensing)
Ambient light
Vibration
Shock
Electromagnetic compatibility
Conformity
Certifications
1) For UL applications: only for use in "Class 2" circuits in accordance with NEC, supply
by means of LPS (Limited Power Source)
2) Only if M12 plugs are screwed into place and sealing caps are mounted
3) This is a Class A product. In a domestic environment this product may cause radio
interference, in which case the operator may be required to take adequate measures.
20 ... 30VDC (PELV, Class 2)
Laser / 630... 680nm
2 (in accordance with IEC 60825-1:2007), see
M-optics: max. 1700mm,
N-optics: max. 1525mm,
see operating instructions
M-optics: m = 0.33 ... 0.51mm (13 ... 20mil),
N-optics: m = 0.25 ... 0.38mm (10 ... 15mil)
2/5 Interleaved, Code 39, Code 128, EAN 128,
EAN/UPC, EAN Addendum, Codabar, Code 93,
RS 232, RS 422 Full Duplex,
Ethernet TCP/IP, EtherNet/IP, PROFINET-IO
RS 232
IP 65
II
Approx. 2kg
See
operation/storage
0°C ... +50°C / -20°C ... +70°C
10 ... 90%
Max. 30,000 lux
IEC 60068-2-6, Test Fc
IEC 60068-2-27, Test Ea
EN 55022, IEC 61000-6-2
CE, CDRH
UL 60950-1, CSA C22.2 No. 60950-1
0.72A /
1.3A (when starting up the motor)
1
1000 scans/s
3 (optical coupler, see operating instructions)
2, configurable (see operating instructions)
2)
Diecast aluminum
2
EN
3)
1)
19

Publicidad

Tabla de contenido
loading

Tabla de contenido