Decommissioning, maintenance
CAUTION!
 Do not open the device yourself under any circumstances! There is
otherwise a risk of uncontrolled emission of laser radiation from the
device. The housing of the BCL 8 does not contain any parts that
need to be adjusted or serviced by the user. If faults cannot be
cleared, the device should be switched off and protected against
accidental use.
 Package the device for transport and storage in such a way that is
protected against shock and humidity. Optimum protection is
achieved when using the original packaging. Ensure compliance with
the approved environmental conditions listed in the specifications.
 Do not use aggressive cleaning agents such as thinner or acetone
for cleaning the device.

Technical data

NOTE
Technical data
 Additional specifications and notices for using the device can be
found in the technical description.
Operating voltage
Current consumption (recommended power
supply unit)
Light source / Wavelength
Laser class
Max. output power (peak)
Impulse duration
Scanning rate
Beam exit
Reading distance
Resolution
1)
4.75 ... 5.5 V DC (PELV)
Max. 250 mA (2 W)
Laser / 655nm
2 (acc. to IEC/EN 60825-1:2014),
see
1
1.7mW
<420µs
M optics: 600 scans/s,
N optics: 500 scans/s
On front or lateral with deflecting
mirror
See
4
M optics: m = 0.15 ... 0.5 mm /
6 ... 20 mil,
N optics: m = 0.127 ... 0.4 mm /
5 ... 16 mil