EN
Technical data
NOTE
Technical data
Additional specifications and notices for using the device can be found in the
technical description.
Operating voltage without/with heating
Power consumption without/with heating
Light source / Wavelength
Laser class
Scanning rate
Reading distance
Resolution
Code types
Interface type
Service interface
Switching inputs/outputs
Degree of protection
VDE safety class
Housing
Weight
Dimensions
22
1)
10 ... 30VDC / 24VDC ± 20%,
(PELV, Class 2)
≤
14W /
Laser / 655nm
2 (in accordance with IEC 60825-1:2007),
see
1
800 ... 1200 scans/s
N-optics: max. 650mm,
M-optics: max. 1000mm,
F-optics: max. 1600mm,
L-optics: max. 2400mm,
see technical description
N-optics: m = 0.25 ... 0.5mm,
M-optics: m = 0.35 ... 0.8mm,
F-optics: m = 0.5 ... 1.0mm,
L-optics: m = 0.7 ... 1.0mm
2/5 Interleaved,
Code 39,
Code 128,
EAN 128,
EAN/UPC,
Codabar,
Code 93,
GS1 DataBar
RS 232,
RS 422,
RS 485,
PROFIBUS DP,
Ethernet,
PROFINET,
EtherNet/IP,
see
4
USB 1.1 (standard A)
4, configurable
IP 65
III
Diecast aluminum
1100 ... 1500g
See
2
≤
75W