Default Functioning; Enabling Self-Teach - Aprimatic SWING 230 APRICODE Instrucciones Para La Instalación Electrica, El Uso Y El Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Hydraulic operators with hydraulic slowing only during closing
use electronic slowing only during OPENING (the START
command must be given when the wing reaches the point
at which you require slowing to start). However during
CLOSING 2 START commands must be given in quick
succession (within 2 seconds of each other) once the wing
reaches the mechanical stop (WARNING:
Note: the electronic slowing must involve a minimum
movement arc of approximately 15-20°.
Note: if you do not want to use the electronic slowing, give 2
START commands in quick succession (within 2 seconds of
each other) when the wing reaches the mechanical stop.
Hydraulic operators fitted with hydraulic slowing during
opening and closing require the unit to learn the slowing
start points performed by the operator itself, therefore the
START command must be given as soon as wing slowing is
rEL
observed (WARNING:
=0).
(
STOP
START
MECHANICAL STOP
START
(
)
SLOWING
*
ELECTRONIC SLOWING
START when the wing
reaches the point at which
you require slowing to
start
START
SLOWING START
3.3

DEFAULT functioning

After the self-teach procedure the default functioning mode
is AUTOMATIC and with the factory settings (see the table
in the section entitled Programming).
See the section entitled Programming to modify the
functioning parameters.
AUTOMATIC MODE (default logic) (
The complete operating cycle is a follows: START with the
gate closed
the gate opens completely
for the PAUSE TIME set
time.
For the responses to the controls and input signals during the
functioning cycle: see the section entitled Functioning.
3.4

Enabling self-teach

IT WILL BE NECESSARY TO:
re-enable self-teaching (see fi g.7) and switch OFF then
switch ON the control unit, IF it had been modifi ed:
- number of motors connected;
- connection to the electric lock;
- speed adjustment (RF valves) on the hydraulic operators.
re-perform the self-teach movements:
Lrn
- each time
flashes on the display (after RESET or
modification of the "approach speed" parameter (
MoD
Model (
).
SWING APRICODE 230
rEL
=1).
)
*
SLOWING START
*
HYDRAULIC SLOWING
START as soon as you
observe the wing slowing
START
SLOWING
Lo
0
.
)
remains open
closes at the end of the pause
A9
), or
Single/twin wing
movements (motor M1)
M1 opens
START
ELECTRONIC SLOWING
Or
HYDRAULIC SLOWING
START
movement end
(only in the case of two wings)
START
M1 closes
START
ELECTRONIC SLOWING
Or
HYDRAULIC SLOWING
START
movement end M1
END: gate closed and stopped - the displays are switched OFF
fi g. 6 -
SELF-TEACH movements
Press the YELLOW
and BLUE buttons
simultaneously for
a p p r o x i m a t e l y 3
Lrn
seconds.
fl ashes
on the display.
IMPORTANT: to start self-teaching
the gate must be stopped and
closed. Use the special control to
close the gate.
fi g. 7 -
Enabling SELF-TEACH
- 21 -
CONTROL UNIT
Only twin wing movements
(motor M2)
START
M2 opens
START
ELECTRONIC SLOWING
Or
HYDRAULIC SLOWING
START
movement end
START
M2 closes
START
ELECTRONIC SLOWING
Or
HYDRAULIC SLOWING
START
movement end M2
START
L r N _ -
display
during
3 "
START
START
LRn

Publicidad

Tabla de contenido
loading

Tabla de contenido