Wire Diagram - Beninca BRAIN 24 Manual De Instrucciones

Ocultar thumbs Ver también para BRAIN 24:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
Wire connections shown in Fig. 1 are described hereunder:
Terminal No.
Function
1-2
Motor 1
3-4
Motor 2
5-6
Flashing light
7-8
Lock
9-10
SCA/SRL
11-12
24 Vac/dc
13
COM
14
SWO1
15
SWC1
16
SWO2
17
SWC2
18
PHOT
19
PHOT C
20
STOP
21
OPEN
22
CLOSE
23
PED
24
Step-by-Step
25
COM
26-27
BAR
28-29
RX 2ch
30-31
Antenna
JF1-JF2
24VAC/dc
The programming of the various functions of the control unit is carried out using the LCD display on the control unit and setting
the desired values in the programming menus described below.
The parameters menu allows you to assign a numerical value to a function, in the same way as a regulating trimmer.
The logic menu allows you to activate or deactivate a function, in the same way as setting a dip-switch.
Other special functions follow the parameters and logic menus and may vary depending on the type of control unit or the software
release.
1 – Press the button <PG>, the display goes to the first menu, Parameters "PAR".
2 – With the <+> or <-> button, select the menu you want (PAR>>LOG>>NMAN>>RES).
3- Press the button <PG>, the display shows the first function available on the menu.
4 - With the <+> or <-> button, select the function you want.
5 - Press the button <PG>, the display shows the value currently set for the function selected.
6 - With the <+> or <-> button, select the value you intend to assign to the function.
7 - Press the button <PG>, the display shows the signal "PRG" which indicates that programming has been completed.
Simultaneously pressing <+> and <-> from inside a function menu allows you to return to the previous menu without making any
changes. Hold down the <+> key or the <-> key to accelerate the increase/decrease of the values.
After waiting 30s the control unit quits programming mode and switches off the display.
BRAIN 24 CONTROL UNIT

WIRE DIAGRAM

Description
Connection, motor 1: 24VDC 120W max
Connection, motor 2: 24VDC 120W max
Connection, flashing light 24VDC 15W max.
Output, 12VAC/10W (5s) power supply for electric lock (7:0V, 8:+12V)
Normally open clean contact. Controlled by "SRL" logic.
With SRL logic Off: SCA contact, open gate indicator.
With SRL logic Off: it performs the contact function of the courtesy light control, see table
of logic.
Output, accessory power supply, 24VAC/0.5A max.
IMPORTANT: If the battery charger board CB.24V is installed, the output (without mains
power connected) has a 24Vdc polarised voltage.
Make sure the devices are correctly connected (i.e. 11:+24Vdc / 12:-0Vdc).
Common for limit switches and all control inputs.
Input, OPEN limit switch, motor 1 (Normally closed contact)
Input, CLOSE limit switch, motor 1 (Normally closed contact)
Input, OPEN limit switch, motor 2 (Normally closed contact)
Input, CLOSE limit switch, motor 2 (Normally closed contact)
Input, photocell activated in both opening and closing phases
Input, photocell activated in closing phase only
Input, STOP push-button (Normally closed contact)
Input, OPEN push-button (Normally open contact).
Input, CLOSE push-button (Normally open contact)
Input, push-button for pedestrian use (Normally open contact), it controls the complete
opening of motor 1
Input, step-by-step push button (Normally open contact)
Common for all control inputs.
Input, sensitive edge contact
Resistive edge: "DAS" Jumper closed
Mechanical edge: "DAS" Jumper open
When the edge is activated, the gate movement is stopped and reversed for about 3s.
Output, second radio channel of the receiver.
N.O. contact, voltage-free.
Connection to the insertable radio receiver card (30-signal/31-screen).
Input, 24VAC/24VDC power supply.
If buffer batteries are used, connect the CB.24V card (in option) as indicated in the table.
PROGRAMMING
TO ACCESS PROGRAMMING:
NOTES:
11

Publicidad

Tabla de contenido
loading

Tabla de contenido