Wire connections shown in Fig. 1 are described hereunder:
Terminal No.
Function
1-2
Motor 1
3-4
Motor 2
5-6
Flashing light
7-8
Lock
9-10
SCA/SRL
11-12
24 Vac/dc
13
COM
14
SWO1
15
SWC1
16
SWO2
17
SWC2
18
PHOT
19
PHOT C
20
STOP
21
OPEN
22
CLOSE
23
PED
24
Step-by-Step
25
COM
26-27
BAR
30-31
Antenna
JF1-JF2
24VAC/dc
In case of power failure, an optional accessory to power the control unit is available.
The CB.24V card must be connected between the secondary transformer and the 24V+/24V- inputs, as shown in the diagram of
Fig.2.
During mains powered operation, the DL2 green LED is switched on and the card maintains the battery charged.
If no mains power is available, the card powers the system through batteries, the DL1 red LED switches on.
A F10A fuse protects the control unit during operation with an emergency battery.
If no main power is available and batteries are down, both LED's are switched.
The buffer battery works and progressively runs down until it reaches the value of 18V. When this value is reached, the battery is
disconnected. During operation in case of power failure, the output, 24VAC accessories of the control unit, is polarised.
The programming of the various functions of the control unit is carried out using the LCD display on the control unit and setting
the desired values in the programming menus described below.
The parameters menu allows you to assign a numerical value to a function, in the same way as a regulating trimmer.
The logic menu allows you to activate or deactivate a function, in the same way as setting a dip-switch.
Other special functions follow the parameters and logic menus and may vary depending on the type of control unit or the software
release.
CP.RI624N CONTROL UNIT

WIRE DIAGRAM

Description
Connection, motor 1: 24VDC 120W max
Connection, motor 2: 24VDC 120W max
Connection, flashing light 24VDC 15W max.
Output, 12VAC/10W (5s) power supply for electric lock (7:0V, 8:+12V)
Normally open clean contact. Controlled by "SRL" logic.
With SRL logic Off: SCA contact, open gate indicator.
With SRL logic Off: it performs the contact function of the courtesy light control, see table
of logic.
Output, accessory power supply, 24VAC/0.5A max.
IMPORTANT: If the battery charger board CB.24V is installed, the output (without mains
power connected) has a 24Vdc polarised voltage.
Make sure the devices are correctly connected (i.e. 11:+24Vdc / 12:-0Vdc).
Common for limit switches and all control inputs.
Input, OPEN limit switch, motor 1 (Normally closed contact)
Input, CLOSE limit switch, motor 1 (Normally closed contact)
Input, OPEN limit switch, motor 2 (Normally closed contact)
Input, CLOSE limit switch, motor 2 (Normally closed contact)
Input, photocell activated in both opening and closing phases
Input, photocell activated in closing phase only
Input, STOP push-button (Normally closed contact)
Input, OPEN push-button (Normally open contact).
Input, CLOSE push-button (Normally open contact)
Input, push-button for pedestrian use (Normally open contact), it controls the complete
opening of motor 1
Input, step-by-step push button (Normally open contact)
Common for all control inputs.
Input, sensitive edge contact
Resistive edge: "DAS" Jumper closed
Mechanical edge: "DAS" Jumper open
When the edge is activated, the gate movement is stopped and reversed for about 3s.
Connection to the insertable radio receiver card (30-signal/31-screen).
Input, 24VAC/24VDC power supply.
If buffer batteries are used, connect the CB.24V card (in option) as indicated in the table.
EMERGENCY BATTERY
PROGRAMMING
11