1 – Press the button <PG>, the display goes to the first menu, Parameters "PAR".
2 – With the <+> or <-> button, select the menu you want (PAR>>LOG>>NMAN>>RES>>PAR>>....).
3- Press the button <PG>, the display shows the first function available on the menu.
4 - With the <+> or <-> button, select the function you want.
5 - Press the button <PG>, the display shows the value currently set for the function selected.
6 - With the <+> or <-> button, select the value you intend to assign to the function.
7 - Press the button <PG>, the display shows the signal "PRG" which indicates that programming has been completed.
Simultaneously pressing <+> and <-> from inside a function menu allows you to return to the previous menu without making any
changes.
Simultaneously pressing <+> and <-> when the display is switched off shows the card software release.
Hold down the <+> key or the <-> key to accelerate the increase/decrease of the values.
After waiting 60s the control unit quits programming mode and switches off the display.
The tables below describe the individual functions available in the control unit.
MENU
Automatic closing time. Active only with logic "TCA"=ON.
TCA
At the end of the set time the control unit orders a closing manoeuvre.
Operating time, motor 1. The operating time is adjusted at normal speed
TM1
during motor 1 opening and closing phases. See Paragraph "Adjustment of
the gate leaf speed"
Operating time, motor 2. The operating time is adjusted at normal speed
TM2
during motor 2 opening and closing phases. See Paragraph "Adjustment of
the gate leaf speed"
The opening percentage of motor 1 (pedestrian function) is adjusted.
TPED
If the logics NOLS=OFF, the opening percentage will always be 100%, in
spite of the preset value.
Duration of braking. Preset a value which must be higher than the braking.
TSLD
See section "Adjustment of speed"
PMo1
The torque applied to motor 1 during the opening phase is adjusted.*
PMC1
The torque applied to motor 1 during the closing phase is adjusted.*
PMo2
The torque applied to motor 2 during the opening phase is adjusted.*
PMc2
The torque applied to motor 2 during the closing phase is adjusted.*
Mot.2 opening delay time.
TDMo
Regulates the delay time of motor 2 on opening with respect to motor 1
Mot.1 closing delay time
TDMC
Regulates the delay time of motor 1 on closing with respect to motor 2
Electric lock activation time. If the electric lock is not used, set the param-
TLOc
eter at 0.
Motor speed during braking is adjusted. Values are expressed in percent-
age with respect to normal operating speed.
SLDs
The torque applied to motor 1 during braking in the opening phase is ad-
Pso1
justed *
The torque applied to motor 1 during braking in the closing phase is ad-
Psc1
justed *
The torque applied to motor 2 during braking in the opening phase is ad-
Pso2
justed *
The torque applied to motor 2 during braking in the closing phase is ad-
Psc2
justed *
* WARNING: AN INCORRECT SETTING OF THESE PARAMETERS MAY RESULT IN AN HAZARD.
12
TO ACCESS PROGRAMMING:
NOTES:
PARAMETERS, LOGIC AND SPECIAL FUNCTIONS
FUNCTION
COMPLY WITH REGULATIONS IN FORCE!
MEMO
MIN-MAX-(Default)
1-240-(40s)
5-180-(30s)
5-180-(5s)
25-100-(50%)
1-30-(15s)
1-99-(50%)
1-99-(50%)
1-99-(50%)
1-99-(50%)
0-15-(0s)
0-40-(0s)
0-5-(2s)
20-99 (50)
1-99-(50%)
1-99-(50%)
1-99-(50%)
1-99-(50%)