Beninca BRAINY 24 Manual De Instrucciones página 17

Ocultar thumbs Ver también para BRAINY 24:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 37
MENU
Enables or disables automatic closing
TCA
On: automatic closing enabled
Off: automatic closing disabled
Enables or disables condominium function.
On: condominium function enabled. The step-by-step impulse or transmitter impulse has
IbL
no effect during the opening phase.
Off: condominium function disabled.
The multi-flat function is enabled or disabled during the TCA counting.
On: the bloc of flat function is enabled. The Step-by-Step signal or the transmitter signal
ibca
has no effect during the TCA counting.
Off: the bloc of flat function is disabled.
Enables or disables rapid closing
On: rapid closure is enabled. With open gate, or in the opening phase, the activation of
SCL
the photocell causes the automatic closure 3sec after the total opening of the gate. It is
activated only with TCA:ON
Off: rapid closing disabled.
Selects the operating mode of the "Step by step button" and of the transmitter.
PP
On: Operation: OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Enables or disables pre-blinking.
PRE
On: Pre-blinking enabled. Blinking is activated 3s before the motor starts.
Off: Pre-blinking disabled.
Enables or disables the inversion stroke function
On: Function enabled. Before each opening manoeuvre the control unit orders a manoeuvre
HAM
of 2s in the opposite direction to facilitate the release of the electric lock.
Off: Function disabled.
Enables or disables the block function in opening.
On: Block function enabled. To use only with motors equipped with Limit switch. After
Blco
the intervention of the opening Limit switch the control unit delays arrest by about 0.5s, so
to allow a better strike of the shutter on the stop locks.
Off: Block function disabled
Enables or disables the block function in closing.
On: Block function enabled. To use only with motors equipped with Limit switch. After
Blcc
the intervention of the opening Limit switch the control unit delays arrest by about 0.5s, so
to allow a better strike of the shutter on the stop locks.
Off: Block function disabled.
Enables or disables start at decreased speed.
SOFT
On: Executes start ups at decreased speed for 2 seconds to then shift to normal speed.
Off: Start at decreased speed not active.
Selects the operating mode of the blinking light during the time TCA
LTCA
On: Blinking light on during TCA
Off: Blinking light off during TCA
Enabled or disables HOLD-TO-RUN function
On: HOLD-TO-RUN function.
The pressure of the OPENS/CLOSES button must be maintained throughout the entire ma-
htr
noeuvre. The opening of the STOP input stops the motor. All the safety inputs are deactivated,
except for the Limit switch inputs /SW01/SW02/SWC1/SWC2).
Off: Automatic/semiautomatic function
The operating mode with 1 or 2 motors is selected:
On: The motor operation is synchronised. This function must be used in the following cases:
- for each single motor, connect it to M1: Terminals 1/2.
- for two synchronised motors (e.g. balancing doors), connect one motor to M1: terminals
1mot
1/2 and the other to M2: terminals 3/4. Adjust the parameters related to motor 1, the M2
limit switch inputs are deactivated. TDMO and TDMC must be 0.
Off: For two non-synchronised motors, e.g. overlapping gate leaves, adjust TDMO and
TDMC on the desired values.
The code programmable transmitters is enabled or disabled.
On: Radio receiver enabled only for rolling-code transmitters.
Cvar
Off: Receiver enabled for rolling-code and programmable code transmitters (self-learning
and Dip Switch).
Selects the type of electric lock used.
On: Magnetic electric lock, normally fed at 12Vdc.
Power is cut off to the electric lock output before each opening and closing operation.
mloc
Off: Electric lock with latch, normally not fed.
Before each opening manoeuvre power is fed at 12Vdc for the time set by the parameter
TLOC.
LOGIC (LOG)
FUNCTION
ON-OFF-(Default)
MEMO
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
17

Publicidad

Tabla de contenido
loading

Tabla de contenido