Power Connections - DITEC VIVAH Manual De Instalación

Tablero eléctrico para automación 24 v a 1 o 2 motores
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
1.

POWER CONNECTIONS

1.1 Controls
Control
1
2
N.O.
1
3
N.O.
1
4
N.O.
1
5
N.O.
1
6
N.C.
1
7
N.C.
1
8
N.C.
1
9
N.C.
1
20
N.O.
30
COUPLING BOARD
(OPEN)
WARNING: Make a jumper among all the N.C. contacts if not used. The terminal bearing the same number are equivalent. The
given operating and performance feature can be guaranteed only if original DITEC accessories and safety devices are used.
1.2 SOFA1-SOFA2 self-controlled safety edges
FUTURE USE
Function
AUTOMATIC CLOSURE
OPEN
CLOSE
STEP BY STEP
OPENING SAFETY
CLOSING SAFETY
REVERSAL SAFETY
STOP - CONTROL HOLD
EMERGENCY STOP
PARTIAL OPENING
STEP BY STEP / OPEN
Description
The automatic closure function is enabled by a permanent contact.
It starts the opening operation.
It starts the closing operation.
It starts the closing or opening operation in sequence: open-stop-
close-open. Warning: if the automatic closure is enabled, the stop
is not permanent but lasts for the time set by means of TC.
Stops or inhibits the opening movement by disengaging both door
wings. Refer to TC settings chapter 1.3.
Stops or inhibits the opening movement by disengaging both door
wings. Refer to TC settings chapter 1.3.
Causes reopening movement during closing.
If automation is stopped and jumper SO is closed, it inhibits all
opening and closing operations.
If automation is stopped and jumper SO is cut it inhibits only clo-
sing operation.
Control 1-9 open stops the movement and enables the HOLD TO
RUN function.
In this case, the opening (1-3 / 1-20) and the closing (1-4) controls
operate only if kept pressed, if released the automation will stop.
Safeties, if present, trigger the stop whereas the step-by-step con-
trol and the automatic closing are disabled.
To achieve a complete stop following the opening 1-9 (for example
the emergency stop), connect the opening controls to terminals 9-
3, 9-20 and the closing controls to terminals 9-4 (fig. 2).
Start a partial opening operation of the leaf with motor 1, the dura-
tion of which is established by the RP trimmer, in sequence: partial
opening - stop-close-partial opening.
Warning: if automatic closing is enabled, the stop is not permanent
but at a time that is set by the TC.
DO NOT CONNECT - DO NOT USE
The control panel has two spaces for coupling boards, types radio
receivers, magnetic loops etc. The board's working is selected by
the DIP1 (OFF = 1-5; ON = 1-3).
13
GB
VIVAH - IP1776

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Vivahj

Tabla de contenido