General Safety Precautions; Technical Data; Electrical Connections - DITEC 99 Manual De Instalación

Cuadro electrónico para automación wel
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43

GENERAL SAFETY PRECAUTIONS

This installation manual is intended for professionally competent personnel only. Installation, electrical connections and
adjustments must be performed in accordance with Good Working Methods and in compliance with applicable regulations.
Before installing the product, carefully read the instructions. Bad installation could be hazardous. Before installing the product,
make sure it is in perfect condition. For repairs or replacements of products only original spare parts must be used.
1.

TECHNICAL DATA

Refer to technical data and CE declaration of conformity contained in the manuals for WEL automations.
2.

ELECTRICAL CONNECTIONS

Attention: link up all N.C. contacts (if not used) by means of jumpers. The terminal bearing the same number are equivalent.
2.1 Controls
Control
1
2
N.O.
AUTOMATIC CLOSING
1
3A N.O.
OPENING SIDE A
1
3B N.O.
OPENING SIDE B
1
4
N.O.
CLOSING
41
6 N.C.
OPENING SAFETY
41
8 N.C.
REVERSAL SAFETY CONTACT With J3=ON, the opening of the contact during the closure manoeuvre
1
9
N.C.
STOP
1
29 N.O.
POWER RESET
H
3A N.O.
OPENING SIDE A FOR
HANDICAPPED PEOPLE
H
3B N.O.
OPENING SIDE B FOR
HANDICAPPED PEOPLE
OPEN
OPENING
SETTINGS RESET
2.2 Autocontrolled safety devices
Control
1
6
N.C.
OPENING SAFETY
1
8
N.C.
REVERSAL SAFETY CONTACT The opening of the contact during the closure manoeuvre causes the
41
SAFETY TEST
Function
A permanent contact enables the automatic closing. Selector switches
COMH-K and COME automatically select the automatic closing.
The opening manoeuvre starts when the contact is closed.
The opening manoeuvre starts when the contact is closed.
The closing manoeuvre starts when the contact is closed.
With J3=ON, it stops movement during opening. With contact 41-6 clo-
sed, the interrupted opening operation is restored. If the automation is
closed, contact 41-6 opened prevents opening operation.
causes the movement to invert (opening).
All movements are stopped when the contact is opened. All normal or
emergency operations are excluded when the contact is opened.
Warning: when the contact closes again the door proceeds with the
interrupted manoeuvre.
All acquired data is annulled when the contact is closed.
The automation can start acquisition again after 3 seconds.
It triggers opening operation. The time the door remains open is 30 s
longer than TC.
It triggers opening operation. The time the door remains open is 30 s
longer than TC.
Press shortly to activate opening operation.
Keep OPEN button pressed for 4 s, until IN led starts flashing.
Press again (within 4 s) the OPEN button for 2 s to confirm operation.
This operation allows trimmer and dip-switch settings to prevail over
any DMCS software setting or remote setting by TEL2. Any setting by
means of COME function selector will be eliminated as well.
Function
It stops movement during opening. With contact 1-6 closed, the inter-
rupted opening operation is restored. If the automation is closed, con-
tact 1-6 opened prevents opening operation.
movement to invert (opening).
With J3=ON, connect terminal 41 of the control panel to the correspon-
ding test terminal on the safety device. Terminal 41 activates a test of
the safety device on each cycle. If the test fails the SA led flashes and
the test is repeated.
13
Description
Description
GB
99 - IP1786

Publicidad

Tabla de contenido
loading

Tabla de contenido