Never install the appliance:
- immediately below or in front of a power socket
or a junction box (Fig. 6)
-
-
als or pressure vessels.
Make sure there are no pipes or electric wires in the
wall which could be damaged while mounting the
appliance.
The appliance is equipped with a sensor which can
detect an open window, if present in the proxim-
ity of the towel warmer. For a proper operation, it
is strongly recommended to comply to the instal-
lation directions reported in Ch. 4.3.2 before wall
mounting.

3.1 WALL MOUNTING

Make sure the screws and anchors included in the
mounting pack are suitable for the type of wall on
which you are mounting the appliance. If in doubt,
During installation, make sure the power cable is
disconnected from the power line.
To mount on the wall, see from page 193 of these
instructions.

3.2 ELECTRICAL CONNECTIONS

WARNING
To be installed by a specialised engineer in accord-
ance with the applicable standards in the country
concerned.
Fig. 8
Appliance cable
-
PHASE = BROWN
NEUTRAL = GREY
PILOT WIRE = BLACK
Two possible cases
Case 1: installation
without Pilot Wire
Case 2: installation
with Pilot Wire
15
When the appliance is installed, make sure the
power is off and the mains switch is in the "O" po-
sition.
The appliance requires a 230 V~ 50 Hz power sup-
ply. Make sure the power line is appropriate for the
data given in table 1.
connecting switch allowing the appliance to be dis-
connected completely from the household mains,
included the Pilot Wire, when present, in accord-
ance with the wiring rules.
If the appliance is installed in a bathroom, the
sensitivity residual current protection device). The
power supply line and Pilot Wire control unit must
be protected by the same RCD.
Permanently connected appliances must be con-
nected using a connector block placed within a
proper junction box.
When installing the appliance in damp rooms
(kitchen, bathroom), the point of connection with
the household mains must be at least 25 cm from
If the Pilot Wire is not connected to the
programming unit, it must be terminat-
ed and insulated. Under no circumstanc-
es should the Pilot Wire be connected to
the earth.
Make sure the power cable cannot in any way
come into contact with the surface of the appli-
ance (Fig. 7).
PHASE
Household mains
NEUTRAL
Terminate and insulate
the wire
Connect to the Pilot Wire control unit or
transmission box