Show/Hide Bookmarks
2
Safety
General safety and application notes for Lenze motors
Operation
Vibration severities v
when the clutch is activated. If deviations from normal operation occur, e.g. increased
temperatures, noises, vibrations, find the cause and, if necessary, contact the
manufacturer. Switch off the machine in problematic situations.
If the drive is exposed to dirt, clean it regularly.
Do not switch off the protection devices, not even for trial runs.
Integrated temperature sensors do not provide full protection. If necessary, limit the
maximum current. Connect the function blocks such that the machine switches off after
several seconds of operation at I > I
Shaft seals and bearings have a limited service life.
Regrease the bearings using the relubrication facility while the low-voltage machine is
running. Observe the saponification number. If the grease drain hole is sealed with a plug
(IP54 driven end; IP23 driven end and non-driven end), remove the plug before
commissioning. Seal the bore holes with grease. Replace the prelubricated bearings (2Z
bearings) after approx. 10,000 h - 20,000 h, at the latest however after 3 - 4 years. Observe
the manufacturer's instructions.
26
≤ 3.5 mm/s (P
≤ 15 kW) and 4.5 mm/s (P
rms
r
, especially if blocking may occur.
r
> 15 kW) are acceptable
r
EDKCSXX0XX DE/EN/FR/ES/IT 4.0