9.5 - SIGNALLING
The receiver is furnished with two signalling LEDs, controlled according to CiA DR-303-3
recommendation:
CAN-RUN (green): indicates the system state inside the CANopen machine state:
-
-
-
CAN-ERR (red): indicates error if switched on; in normal conditions it must be switched off.

9.6 - TM70 CAN RECEIVERS

Ref. 3302750 (7503 70GR401 RX R70CANC3 433)
Ref. 3302751 (7504 70GR903 RX R70CANC3 915)
R70CANC3 RECEIVER
Available frecuencies (ISM bands)
Power supply / Maximum consumption
Inputs / Outputs interface
Ingress protection
Antenna
Working frequency selection
Weight
Dimensions
EEPROM

Signaling

Connexions
STOP function
CAN BUS termination (120 Ohm)
Passive STOP time
Input protection
Output protections (STOP)
Operating mode temperatura range
Storage temperatura (24h)
Storage temperature –long periods-
TM70 range supported transmitters
Available complete systems
TM70Bi V4.1 (03/12)
1121174.pdf
IKUSI reserves the right to modify this information without prior notification.
Blinking every 200 ms. In preoperational state.
Solid green permanently in operational state.
One blink every second in stop state.
Specifications
915MHz (FCC certified)
433MHz
9-35v DC / 5W maximum
CAN:Standard CAN Open protocol 401 (CIA DS401)
IP67 / NEMA-6
External: NEARSON S325TR-015 or equivalent
Automatic: LBT (listen before talking)
430 gr.
Long = 151mm / Width = 129mm (160mm with PG) /
Height = 61mm
Extractable EP70 module
MultiLED:
7 external LEDS (6 green + 1 bicoloured)
2 internal LEDS (CAN status: 1 red + 1 green)
Fast PLUG-IN plugs and 2 x M16 cable glands
1) Power supply cable gland: M16 / IP67
2) Inputs / Outputs interface cable gland: M16 / IP67
Cat. 3 Pl=c En 13849-1 / 2 STOP relays: 250V / 6A
maximum STOP response time = 50 miliseconds
ON / OFF jumper (internal)
Programmable: 0,5 to 2 seconds (máx)
PTC / 0,3A fuse
VDR in contacts
-20ºC / +70ºC (-4ºF / 158ºF)
-25ºC / +75ºC (-13ºF / 167ºF)
-25ºC / +55ºC (-13ºF / 131ºF)
T70/1/2; T70/3/4; T70/5/6; T70/7/8
Ref. 3302XXX Equipo comp. TM70/X.CAN-C1-915
27