OUTPUTS
The voltage outputs are generated from PWM pulses, and them filtered result in radiometric tension outputs
(dependent on supply voltage). The two outputs are electrically isolated respect to the logic and each other.
The control of relays is done via VREL1 and VREL2 signals. Also, it needs to be activated the common of both
relays by VCOMREL signal. When the relays are off, the output voltage VO1 and VO2 are the values of
reference voltage VR1 and VR2 connected at each output.
The output values range goes from 0 to 100% of power supplies VPP1 and VPP2 connected to each of the
outputs and have a resolution of 10 bits (1024 values).
OUTPUT 1 (VO1)
The connections of the output 1 are through 4 pole terminal plug, with the follow pin assignment:
Output 1 connector
Pin Name
VPP1
GND1
VO1
VR1
OUTPUT 2 (VO2)
The connections of the output 1 are through 4 pole terminal plug, with the follow pin assignment:
Output 2 connector
Pin name
VPP2
GND2
VO2
VR2
ISP connector
Pin name
ISP2
TX2
RX2
GND
RX1
TX1
ISP
VCC
MRNOT
+VI
TM70Bi V4.1 (03/12)
1121174.pdf
IKUSI reserves the right to modify this information without prior notification.
Function
Power of channel 1
Ground of channel 1
Analogue output of channel 1
Zero position signal signal to get through the output 1 when the relay is inactive
Function
Power of channel 2
Ground of channel 2
Analogue output of channel 2
Zero position signal signal to get through the output 2 when the relay is inactive
Function
Input connected to the ground to place the microcontroller in recording mode
Not used
Receiving data signal
Ground
Receiving data signal
Transmisión data signal
Not used
Power supply output at 3,3 V
Reset input, active when it is connected to ground
Power supply output at 12 V (not stabilized, can vary between 8 y 22 V)
74