RELAY OUTPUTS
The following connections are available for each relay: normally open (NO), normally closed (NC) and common,
in the RL1 connector as shown in the following table. Disposition of 4 manoeuvre relays of 250V/8A.
Pin
1
2
3
4
5
6
7
8
9
10
11
12
ANALOGUE OUTPUT
The analogue output is connected through RL2 connector with the following signals (Imax=15mA):
Pin
Name
1
VOUT
2
GND
3
-V
4
+V
TM70Bi V4.1 (03/12)
1121174.pdf
IKUSI reserves the right to modify this information without prior notification.
Function
K1 contact: normally closed
K1 common contact
K1 contact: normally opened
K2 contact: normally closed
K2 common contact
K2 contact: normally opened
K3 contact: normally closed
K3 common contact
K3 contact: normally opened
K4 contact: normally closed
K4 common contact
K3 contact: normally opened
Function
Analogue Output
Potentiometer's middle point
Negative power supply (Minimun: -50V)
Positive power supply (Maximun: 50V)